![SMC Networks LECSB Series Operation Manual Download Page 91](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641091.webp)
3 - 55
3. SIGNALS AND WIRING
3.8.3 Source I/O interfaces
In this driver, source type I/O interfaces can be used. In this case, all DI-1 input signals and DO-1 output
signals are of source type. Perform wiring according to the following interfaces.
(1) Digital input interface DI-1
Servo amplifier
Switch
Approx. 5mA
V
CES
1.0V
I
CEO
100 A
24VDC 10
300mA
Approx. 5.6k
SON,
etc.
DICOM
(2) Digital output interface DO-1
A maximum of 2.6V voltage drop occurs in the driver.
(Note)
If polarity of diode is
reversed, servo
amplifier will fail.
24VDC 10
300mA
Servo amplifier
ALM,
etc.
Load
DOCOM
Note. If the voltage drop (maximum of 2.6V) interferes with the relay operation, apply high
voltage (up to 26.4V) from external source.
Driver
Driver
driver