5 - 44
5. PARAMETERS
(2) Set content
The driver is factory-set to output the servo motor speed to analog monitor 1 (MO1) and the torque to
analog monitor (MO2). The setting can be changed as listed below by changing the parameter No.PC14
and PC15 value.
Refer to (3) for the measurement point.
Setting
Output item
Description
Setting
Output item
Description
0
Servo motor speed
Max. speed
CW direction
CCW direction
Max. speed
0
8[V]
-8[V]
1
Torque (Note 3)
Max. torque
Driving in CW
direction
Driving in CCW
direction
Max. torque
0
8[V]
-8[V]
2
Servo motor speed
CCW direction
Max. speed
Max. speed
0
8[V]
CW direction
3
Torque (Note 3)
Driving in CCW
direction
Max. torque
Max. torque
0
8[V]
Driving in CW
direction
4
Current command
Max. current command
(Max. torque command)
CW direction
CCW direction
Max. current command
(Max. torque command)
0
8[V]
-8[V]
5
Command pulse
frequency
1M[kpps]
CW direction
CCW direction
1M[kpps]
0
10[V]
-10[V]