![SMC Networks LECSB Series Operation Manual Download Page 411](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641411.webp)
App. - 2
APPENDIX
App. 1 Parameter list
POINT
For any parameter whose symbol is preceded by *, set the parameter value and
switch power off once, then switch it on again to make that parameter setting
valid.
App. 1.1 Driver (drive unit)
Basic setting parameters (PA
)
Gain/filter parameters (PB
)
No.
Symbol
Name
Control
mode
No.
Symbol
Name
Control
mode
PA01
*STY
Control mode
P
S
T PB01
FILT
Adaptive tuning mode (Adaptive filter )
P
S
PA02
*REG Regenerative option
P
S
T PB02 VRFT Vibration suppression control tuning
mode (Advanced vibration suppression
control)
P
PA03
*ABS
Absolute position detection
system
P
PB03
PST
Position command acceleration/
deceleration time constant
(Position smoothing)
P
PA04 *AOP1 Function selection A-1
P
S
T
PA05
*FBP
Number of command input
pulses per revolution
P
PB04
FFC
Feed forward gain
P
PA06
CMX
Electronic gear numerator
(Command pulse multiplying
factor numerator)
P
PB05
For manufacturer setting
PB06
GD2
Ratio of load inertia moment to servo
motor inertia moment
P
S
PA07
CDV
Electronic gear denominator
(Command pulse multiplying
factor denominator)
P
PB07
PG1
Model loop gain
P
PB08
PG2
Position loop gain
P
PB09
VG2
Speed loop gain
P
S
PA08
ATU
Auto tuning mode
P
S
PB10
VIC
Speed integral compensation
P
S
PA09
RSP
Auto tuning response
P
S
PB11
VDC
Speed differential compensation
P
S
PA10
INP
Control mode, regenerative
option selection
P
PB12
OVA
Overshoot amount compensation
P
S
PB13
NH1
Machine resonance suppression filter 1
P
S
PA11
TLP
Forward rotation torque limit
P
S
T PB14 NHQ1 Notch shape selection 1
P
PA12
TLN
Reverse rotation torque limit
P
S
T PB15
NH2
Machine resonance suppression filter 2
P
PA13 *PLSS Command pulse input form
P
PB16 NHQ2 Notch shape selection 2
P
PA14
*POL
Rotation direction selection
P
PB17
Automatic setting parameter
PA15
*ENR
Encoder output pulses
P
S
T PB18
LPF
Low-pass filter setting
P
PA16
For manufacturer setting
PB19 VRF1 Vibration suppression control vibration
frequency setting
P
to
PA18
PB20 VRF2 Vibration suppression control resonance
frequency setting
P
PA19
*BLK
Parameter write inhibit
P
S
T
PB21
For manufacturer setting
PB22
PB23 VFBF Low-pass filter selection
P
PB24 *MVS Slight vibration suppression control
selection
P
S
PB25 *BOP1 Function selection B-1
P
PB26 *CDP
Gain changing selection
P
S
PB27
CDL
Gain changing condition
P
S
PB28
CDT
Gain changing time constant
P
S
PB29 GD2B Gain changing ratio of load inertia
moment to servo motor inertia moment
P
S
PB30 PG2B Gain changing position loop gain
P
PB31 VG2B Gain changing speed loop gain
P
S
PB32
VICB
Gain changing speed integral
compensation
P
S
PB33 VRF1B Gain changing vibration suppression
control vibration frequency setting
P
PB34 VRF2B Gain changing vibration suppression
control resonance frequency setting
P
PB35
to
PB44
For manufacturer setting
PB45 CNHF Vibration suppression control filter 2
P