![SMC Networks LECSB Series Operation Manual Download Page 51](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641051.webp)
3 - 15
3. SIGNALS AND WIRING
3.3.3 CNP1, CNP2, CNP3 wiring method
POINT
Refer to section 12.11 for the wire sizes used for wiring.
Use the supplied driver power supply connectors for wiring of CNP1, CNP2 and CNP3.
(1) LECSB
□
-
□
(a) Driver power supply connectors
CNP2
CNP1
CNP3
Connector for CNP1
54928-0670(Molex)
Connector for CNP2
54927-0520(Molex)
Connector for CNP3
54928-0370(Molex)
<Applicable cable example>
Cable finish OD: to 3.8mm
(Note)Servo amplifier Power supply connectors
Servo amplifier
Note. MITSUBISHI ELECTRIC SYSTEM & SERVICE CO., LTD
Please purchase from distributor or distributor of Mitsubishi Electric Corporation.
(b) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
8 to 9mm
Sheath
Core
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to
avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder
the core as it may cause a contact fault. Alternatively, a ferrule may be used to put the
wires together.
Cable size
Ferrule type (Note 1)
Crimping tool (Note 2)
[mm
2
]
AWG
For 1 cable
For 2 cable
1.25/1.5
16
AI 1,5-10 BK
AI-TWIN2
1,5-10 BK
Variocrimp 4 206-204
2/2.5
14
AI 2,5-10 BU
Note 1. Manufacturer: Phoenix Contact
2. Manufacturer: WAGO
Driver
Driver Power supply connectors
200VAC / Part No. K05A50230490
(Note)
100VAC / Part No. K05A50230496
(Note)
Part No. K05A50230491
(Note)
Part No. K05A50230492
(Note)