![SMC Networks LECSB Series Operation Manual Download Page 195](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641195.webp)
6 - 19
6. DISPLAY AND OPERATION SECTIONS
6.9 Test operation mode
CAUTION
The test operation mode is designed to confirm servo operation. Do not use it for
actual operation.
If any operational fault has occurred, stop operation using the emergency stop
(EMG) signal.
POINT
The test operation mode cannot be used in the absolute position detection system
by DIO (parameter No.PA03:
1).
The software (MR Configurator2
TM
) is required to perform positioning operation.
Test operation cannot be performed if the servo-on (SON) is not turned OFF.
6.9.1 Mode change
After power-on, change the display mode to the diagnostic mode using the "MODE" button. Choose JOG
operation/motor-less operation in the following procedure.
Press UP three times.
Flickers in the test operation mode.
Press SET for longer than
2s.
When this screen appears,
JOG operation can be
performed.
Press UP five times.
When this screen is displayed,
motor-less operation can be
performed.
Press SET for longer than 2s.