![SMC Networks LECSB Series Operation Manual Download Page 315](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641315.webp)
13 - 13
13. COMMUNICATION FUNCTION
(4) Alarm history (Command [3][3])
Command
Data No.
Description
Alarm occurrence sequence
Frame length
[3][3]
[1][0]
Alarm number in alarm history
most recent alarm
4
[1][1]
first alarm in past
[1][2]
second alarm in past
[1][3]
third alarm in past
[1][4]
fourth alarm in past
[1][5]
fifth alarm in past
[2][0]
Alarm occurrence time in alarm history
most recent alarm
8
[2][1]
first alarm in past
[2][2]
second alarm in past
[2][3]
third alarm in past
[2][4]
fourth alarm in past
[2][5]
fifth alarm in past
(5) Current alarm (Command [0][2])
Command
Data No.
Description
Frame length
[0][2]
[0][0]
Current alarm number
4