6 - 9
6. DISPLAY AND OPERATION SECTIONS
Name
Display
Description
Automatic VC offset
If offset voltages in the analog circuits inside and outside the driver
cause the servo motor to rotate slowly at the analog speed command
(VC) or analog speed limit (VLA) of 0V, this function automatically
makes zero-adjustment of offset voltages.
When using this function, make it valid in the following procedure.
Making it valid causes the parameter No.PC37 value to be the
automatically adjusted offset voltage.
1) Press "SET" once.
2) Set the number in the first digit to 1 with "UP"/"DOWN".
3) Press "SET".
This function cannot be used if the input voltage of VC or VLA is
0.4V or less, or
0.4V or more.
Servo motor series ID
Press the "SET" button to show the series ID of the servo motor
currently connected.
Servo motor type ID
Press the "SET" button to show the type ID of the servo motor
currently connected.
Servo motor encoder ID
Press the "SET" button to show the encoder ID of the servo motor
currently connected.
For manufacturer setting
For manufacturer setting
For manufacturer setting
For manufacturer setting