13 - 14
13. COMMUNICATION FUNCTION
Command
Data No.
Description
Display item
Frame length
[3][5]
[0][0]
Status display name and unit at alarm
occurrence
Cumulative feedback pulse
16
[0][1]
Servo motor speed
[0][2]
Droop pulse
[0][3]
Cumulative command pulse
[0][4]
Command pulse frequency
[0][5]
Analog speed command voltage
Analog speed limit voltage
[0][6]
Analog torque command voltage
Analog torque limit voltage
[0][7]
Regenerative load ratio
[0][8]
Effective load ratio
[0][9]
Peak load ratio
[0][A]
Instantaneous torque
[0][B]
Within one-revolution position
[0][C]
ABS counter
[0][D]
Load inertia moment ratio
[0][E]
Bus voltage
[8][0]
Status display data value and processing
information at alarm occurrence
Cumulative feedback pulse
12
[8][1]
Servo motor speed
[8][2]
Droop pulse
[8][3]
Cumulative command pulse
[8][4]
Command pulse frequency
[8][5]
Analog speed command voltage
Analog speed limit voltage
[8][6]
Analog torque command voltage
Analog torque limit voltage
[8][7]
Regenerative load ratio
[8][8]
Effective load ratio
[8][9]
Peak load ratio
[8][A]
Instantaneous torque
[8][B]
Within one-revolution position
[8][C]
ABS counter
[8][D]
Load inertia moment ratio
[8][E]
Bus voltage
(6) Test operation mode (Command [0][0])
Command
Data No.
Description
Frame length
[0][0]
[1][2]
Test operation mode read
0000: Normal mode (not test operation mode)
0001: JOG operation
0002: Positioning operation
0003: Motorless operation
0004: Output signal (DO) forced output
4
(7) Others
Command
Data No.
Description
Frame length
[0][2]
[9][0]
Servo motor end pulse unit absolute position
8
[9][1]
Command unit absolute position
8
[7][0]
Software version
16