5. Initial Setting Method
Initial setting of the controller and PLC is necessary for the communication with EtherNet/IP.
5.1 Controller setting (IP address setting)
IP address setting is necessary to distinguish the controller on the EtherNet/IP network. IP address is
set by the rotary switches of the controller.
Use a flat blade watchmaker's screwdriver of the size shown below when setting the rotary switches.
Setup
IP address
x100
x10
x1
0
0
0
Remote Control mode
Note 1)
0
0
1
192.168.1.1 (Factory default value)
0
0
2
192.168.1.2
:
:
:
:
2
5
4
192.168.1.254
2
5
5
DHCP mode
Note 2)
2
5
6
Unused
:
:
:
9
9
9
Note 1) The mode to set IP address by DHCP server.
When "BOOTP/DHCP Server" provided by Rockwell Automation is used after IP address setting,
user is possible to choose whether or not to obtain an IP address by the settings below when
power is supplied to the controller again.
Enable DHCP: Controller acquires an IP address again from the DHCP server when power is
supplied to the controller again. The controller deletes the information of IP
address when the power supply is removed.
Disable DHCP: Controller does not acquire an IP address from the DHCP server when power is
supplied to the controller again. Even when the power supply is removed, the
controller holds the IP address when "Di
sable DHCP” setting is selected.
Note 2) The mode to set IP address by DHCP server.
Controller acquires an IP address again from the DHCP server when power is supplied to the
controller again after setting IP address. The controller deletes the information of IP address
when the power supply is removed.
Caution
(1) The power supply should be off while setting the switches.
This may cause damage to the controller.
(2) If the saved IP address in the Remote Control mode is forgotten, change to DHCP
mode and re-assign the correct IP address.
The saved IP address will be lost. But when return to the Enable DHCP from Disable
BOOTP/DHCP, it is possible to set the new IP address from BOOTP/DHCP server.