APPENDIX B
REMOTELY MANAGING YOUR SMART ROOM SYSTEM
91
smarttech.com/kb/170764
Command
Possible values
Response
Standby
mode
set vposition
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=
[Range of values dependent
on the video signal]
vposition=
[Value]
No
set welcome
[Value]
l
=on
l
=off
welcome=
[Value]
No
set welcometimeout
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=5–30
welcometimeout=
[Value]
No
set zoom
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=100–300
zoom=
[Value]
No
Service information
Use the following commands to identify service information settings.
Command
Response
Possible values
Standby
mode
get displayhour
displayhour=
[Value]
0–20000
Yes
get fancontrol
fancontrol=
[Value]
l
on
l
auto
Yes
get highspeedfan
highspeedfan=
[Value]
l
high
l
normal
No
get totalhours
totalhours=
[Value]
0–20000
Yes
Use the following commands to assign service information settings.
Command
Possible values
Response
Standby
mode
set highspeedfan
[Value]
l
=high
l
=normal
highspeedfan=
[Value]
No
set fancontrol
[Value]
l
=on
l
=auto
fancontrol=
[Value]
Yes
SMART Board 8084i-G4 interactive flat panel
commands
The following tables contain commands for SMART Board 8084i-G4 interactive flat panels.