APPENDIX B
REMOTELY MANAGING YOUR SMART ROOM SYSTEM
98
smarttech.com/kb/170764
Command
Response
Possible values
Standby
mode
get resolution
resolution=
[Value]
[Resolution]
No
get serialnum
serialnum=
[Value]
[Serial number]
No
get tempsensor1
tempsensor1=
[Value]
[Temperature in ºC]
No
get testmode
testmode=
[Value]
l
on
l
off
No
get upgradeicp
upgradeicp=
[Value]
l
on
l
off
No
get upgrademain
upgrademain=
[Value]
l
on
l
off
No
get videomute
videomute=
[Value]
l
on
l
off
No
get vposition
vposition=
[Value]
[Dependent on the video
signal]
No
get welcome
welcome=
[Value]
l
on
l
off
No
get welcometimeout
welcometimeout=
[Value]
5–30
No
Use the following commands to assign system information settings.
Command
Possible values
Response
Standby
mode
set aspectratio
[Value]
l
=justscan
l
=16:9
l
=4:3
aspectratio=
[Value]
No
set autopoweroff
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=15–240
autopoweroff=
[Value]
No
set factoryreset
[Value]
=yes
factoryreset=
[Value]
Yes
set fancontrol
[Value]
l
=auto
l
=25
l
=50
l
=75
l
=100
l
=off
fancontrol=
[Value]
Yes
set fbc
[Value]
l
=on
l
=off
fbc=
[Value]
No
set fwinfotouch
[Value]
=
[User defined value]
fwinfotouch=
[Value]
No
set fwvericp
[Value]
=
[Firmware (ICP) version
number]
fwvericp=
[Value]
Yes
set hposition
[Value]
l
+
[Incremental value]
l
-
[Incremental value]
l
=
[Range of values dependent
on the video signal]
hposition =
[Value]
No