E_MH_Installation_instructions_Skylux_Climax
20/11/2020
60/88
Finish
SIDE SUPPORTS WITH RUBBERS
Finish using seal C2CX for plastic sheets or glass:
The glazing thickness and options are provided in the table on page 83.
For freestanding side support:
For a side support against a wall:
Measure the length of the wall up to the stop profile. Cut side finishing profile L16P obliquely in accordance with
the roof pitch (a). Position the L16P profile between the support and the wall to ensure that the support lip is at
the same height as the top side of the glazing. Fasten the top lip of the L16P profile every 100 cm against the wall.
Push seal C2CX into sheet support TP(G) or into raised profile Y25/Y32. The seal lip will be supported by side finish
profile L16P.
Push seal C2CX into sheet support TP(G) or into raised
profile Y25/Y32. The seal is supported by the lip of side
finish profile ZDC.
Install finish profile ZDCS at the crosscut side of the
side finish profile ZDC using silicone.
C2CX
TPG
ZDC
ZDCS
ZDC
5 mm
L16P
TP(G)
C2CX
Y25/Y32
ZD
L432