Spare parts/accessories
13.5 IR analyzer units
ULTRAMAT 23
220
Manual, 3/2016, A5E37100388-003
Part No.
Designation
Order No.
Remarks
1 *)
IR source
C79451--A3468--B206
2.1
Spacer
C79451--A3468--C20
2.2
Optical filter
C75285--Z1491--C5
For NO **)
2.2
Optical filter
C79285--Z1302--A4
For SO
2
**)
2.2
Optical filter
C79285--Z1491--C2
For C
2
H
4
2.2
Optical filter
A5E00069310
For C
6
H
14
2.2
Optical filter
C79451--A3182--C161
For SF
6
3 *)
Chopper
C79451--A3468--B516
4
Plate with threaded bolts and win-
dows
C79451--A3468--B514
5.1
O-ring
C71121--Z100--A99
5
Analyzer chamber with O-ring
C79451--A3468--B231
180 mm
5
Analyzer chamber with O-ring
C79451--A3468--B232
90 mm
5
Analyzer chamber with O-ring
C79451--A3468--B233
60 mm
5
Analyzer chamber with O-ring
C79451--A3468--B234
20 mm
5
Analyzer chamber
C79451--A3468--B235
6 mm
5
Analyzer chamber
C79451--A3468--B236
2 mm
6
Gas filter
C79451--A3458--B500
For CO
6
Gas filter
C79451--A3458--B508
For SO
2
6
Gas filter
C79451--A3468--B541
For CO
2
; smallest MR <5%
6
Gas filter
C79451--A3468--B542
For CH
4
; smallest MR <2%
6
Gas filter
C79451--A3468--B553
For C
6
H
14
, N
2
O 500/5000 vpm
7.1/7.2 *)
Receiver chamber
C79451--A3468--B525
For CO; smallest MR <5%
7.1/7.2 *)
Receiver chamber
C79451--A3468--B528
For CO; smallest MR ≥5%
7.1/7.2 *)
Receiver chamber
C79451--A3468--B536
For CO
2
; smallest MR <1000 vpm
7.1/7.2 *)
Receiver chamber
C79451--A3468--B526
For CO
2
; smallest MR ≥1000
vpm
7.1/7.2 *)
Receiver chamber
C79451--A3468--B527
For CH
4
; smallest MR <20%
7.1/7.2 *)
Receiver chamber
C79451--A3468--B529
For CH
4
; smallest MR ≥20%
7.1/7.2 *)
Receiver chamber
C79451--A3468--B537
For C
2
H
4
7.2 *)
Receiver chamber
C79451--A3468--B522
For NO (channel 2)
7.1 *)
Receiver chamber
C79451--A3468--B523
For SO
2
(channel 2)
7 *)
Receiver chamber
C79451--A3468--B581
For N
2
O
7 *)
Receiver chamber
C79451--A3468--B539
For SF
6
7 *)
Receiver chamber
C79451--A3468--B538
For C
6
H
14
*) Following replacement of this part, special work is required which can only be carried out by qualified personnel trained
for this task, for example temperature compensation, basic electronic adjustment etc.
**) Following replacement of this part, the water vapor cross-sensitivity must be checked.
Summary of Contents for ULTRAMAT 23
Page 2: ......
Page 10: ...Table of contents ULTRAMAT 23 10 Manual 3 2016 A5E37100388 003 Index 239 ...
Page 66: ...installation ULTRAMAT 23 66 Manual 3 2016 A5E37100388 003 ...
Page 147: ...Functions 8 4 Configuration ULTRAMAT 23 Manual 3 2016 A5E37100388 003 147 ...
Page 160: ...Functions 8 5 Automatically executed functions ULTRAMAT 23 160 Manual 3 2016 A5E37100388 003 ...
Page 194: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 194 Manual 3 2016 A5E37100388 003 ...
Page 195: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 Manual 3 2016 A5E37100388 003 195 ...
Page 196: ...Spare parts accessories 13 5 IR analyzer units ULTRAMAT 23 196 Manual 3 2016 A5E37100388 003 ...
Page 229: ...Appendix A 4 Returned delivery ULTRAMAT 23 Manual 3 2016 A5E37100388 003 229 ...
Page 230: ...Appendix ULTRAMAT 23 230 Manual 3 2016 A5E37100388 003 ...
Page 238: ...List of abbreviations C 1 List of abbreviations ULTRAMAT 23 238 Manual 3 2016 A5E37100388 003 ...