![Siemens SIRIUS 3RH Series System Manual Download Page 544](http://html.mh-extra.com/html/siemens/sirius-3rh-series/sirius-3rh-series_system-manual_383139544.webp)
SIRIUS 3RU2/3RB3 overload relays
5.10 Technical data
SIRIUS Innovations
544
System Manual, 01/2011, A8E56203870002-03
Type
3RU21 16
3RU21 26
Size
S00
S0
Width
45 mm
45 mm
Short-circuit protection
With fuse
- Operating class gL/gG
A
6
- Quick-response
A
10
With miniature circuit breaker
(C characteristic)
A
6
2)
Protective separation between auxiliary
current paths
acc. to IEC/EN 60947-1
V
440
CSA, UL, and UR rated data
Auxiliary circuit – Switching capacity
B600, R300
1)
On request
2)
Up to
I
k
≤ 0.5 kA; ≤ 260 V
5.10.2.5
Conductor cross sections, auxiliary circuit
Table 5- 42 Technical data for the auxiliary circuit connection, 3RU21 overload relays
Type
3RU21 16
3RU21 26
Size
S00
S0
Width
45 mm
45 mm
Connection type
Screw connection
Connection screw
M3, Pozidriv size 2
Operating tool
mm
∅ 5 to 6
Tightening torque
Nm
0.8 to 1.2
Conductor cross-sections (min./max.), 1-wire or 2-wire
- Solid
mm
2
2 x (0.5 to 1.5)
1)
; 2 x (0.75 to 2.5)
1)
- Finely stranded with end sleeve
(DIN 46228 Part 1)
mm
2
2 x (0.5 to 1.5)
1)
; 2 x (0.75 to 2.5)
1)
- AWG cables, solid or stranded AWG
2 x (20 to 16)
1)
, 2 x (18 to 14)
1)
Connection type
Spring-loaded connection
Operating tool
mm
∅ 3.0 x 0.5. ∅ 3.5 x 0.5
Conductor cross-sections (min./max.)
- Solid
mm
2
2 x (0.5 to 2.5)
- Finely stranded without end
sleeve
mm
2
2 x (0.5 to 1.5)
- Finely stranded with end sleeve
(DIN 46228 Part 1)
mm
2
2 x (0.5 to 1.5)
- AWG cables, solid or stranded AWG
2 x (20 to 14)