2.7.9.2
Mounting
Prerequisite
The 3RT2926-4R..... coil terminal module must be mounted before you can attach the
coupling link.
CAUTION
Before mounting the coupling link, disconnect the voltage from L1 to L3.
Step
Operating instruction
Image
1
Attach the coupling link to the coil terminal
module using the two integrated mounting
pins.
2
Screw the coupling link tight with a
screwdriver.