Note
Access rights during the first commissioning
A login is not necessary during first commissioning when opening the web server. You have
full access rights to all functions of the web server like the "Administrator".
However, the following access rights apply when a drive has been commissioned:
Functions of the web server
Access rights
All
SINAMICS
Administrator
Start page / password input
X
X
X
Diagnostic pages (version overview, DO state, alarms,
diagnostic buffer)
–
X
X
Resetting the fault memory
–
X
X
Uploading trace files
–
X
X
Creating/expanding/removing parameter lists
–
X
1)
X
1)
Reading parameters
–
X
2)
X
2)
Writing and saving parameters
–
X
2)
X
2)
Updating the configuration
–
–
X
Updating the firmware
–
–
X
Loading user-defined pages to the drive
–
–
X
1)
Only those lists may be edited for which the user has the appropriate access right. A default setting
applies during creation of the lists depending on the user.
2)
These rights can be individually assigned for a parameter list. A default setting applies here depending
on the user.
Access rights can be set individually for each user and parameter list in the parameter lists via the web
server configuration.
Password assignment
By default, password protection is regulated as follows:
● "SINAMICS" user: No password protection
We recommend that you assign a password. The password must consist of 8 characters
or more.
● "Administrator" user: Password protection. A password is not pre-set.
A password with at least 8 characters must be assigned. If a password has not been
assigned, the following alarm appears when attempting to log in: "A09000: Web server
security: Administrator password not set”.
After the first commissioning, the passwords for the two users can only be defined or changed
via the STARTER configuration. If reset to factory settings, the passwords are reverted to their
initial settings.
To change a password, you must know the existing password.
When the corresponding website is accessed, you will be prompted once to enter the
password.
Security measures for SINAMICS
5.6 Web server
Industrial Security
60
Configuration Manual, 08/2017, A5E36912609A