● Physical word and double word values are inserted in the telegram as referenced variables.
● p200x apply as reference variables (telegram contents = 4000 hex or 4000 0000 hex in the
case of double words if the input variable has the value p200x).
162//B$
162//B%
Q
S
KH[
KH[
Figure A-2
Scaling of speed
You can find the detailed structure of the telegrams in the converter List Manual in the
associated function diagrams.
Which drive objects support which telegrams?
Drive object
Telegrams (p0922)
Function dia‐
grams
A_INF
370, 371, 999
2421, 2423
B_INF
370, 371, 999
2421, 2423
S_INF
370, 371, 999
2421, 2423
VECTOR
1, 2, 3, 4, 20, 220, 352, 999
2415, 2416,
2421
ENC
81, 82, 83, 999
2416, 2423
TM15DI_DO
No predefined telegram.
‑
HLA
166, 999
2415, 2420
TM31
No predefined telegram.
‑
TM41
3, 999
2415, 2423
TM120
No predefined telegram.
‑
TM150
No predefined telegram.
‑
TB30
No predefined telegram.
‑
CU_S
390, 391, 392, 393, 394, 395, 999
2422, 2423
Depending on the drive object, different process data (PZD) can be sent and received:
Drive objects
Maximum number of PZD
Send
Receive
A_INF
10
10
B_INF
10
10
S_INF
10
10
VECTOR
32
32
ENC
12
4
TM15DI_DO
5
5
TM31
5
5
TM41
28
20
TM120
5
5
Communication
A.1 Communication
Industrial Security
Configuration Manual, 08/2017, A5E36912609A