Siemens Drive Object, Instance Number: 32C hex
Supported services
Class
● Get Attribute single
Instance ● Get Attribute single
● Set Attribute single
Table A-39
Class Attribute
No.
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table A-40
Instance Attribute
No.
Service
Name
Value/explanation
2
get, set
Commisioning state
p0010 Commissioning, parameter filter
3 … 18
get
STW1
STW1 bit-by-bit access:
Attr.3 = STW1.0
Attr.18 = STW1.15
19
get
Main setpoint
Main setpoint
20 … 35
get
ZSW1
ZSW1 bit-by-bit access:
Attr.20 = ZSW1.0
Attr.35 = ZSW1.15
36
get
Actual Frequency
Main actual value (actual frequency)
37
get, set
Ramp Up Time
p1120[0] ramp-function generator
ramp-up time
38
get, set
Ramp Down Time
p1121[0] ramp-function generator
ramp-down time
39
get, set
Current Limit
p0640[0] current limit
40
get, set
Frequency MAX Limit
p1082[0] maximum speed
41
get, set
Frequency MIN Limit
p1080[0] minimum speed
42
get, set
OFF3 Ramp Down Time p1135[0] OFF3 ramp-down time
43
get, set
PID Enable
p2200[0] technology controller enable
44
get, set
PID Filter Time Con‐
stant
p2265 Technology controller actual val‐
ue filter time constant
45
get, set
PID D Gain
p2274 technology controller differen‐
tiation time constant
46
get, set
PID P Gain
p2280 Technology controller propor‐
tional gain
47
get, set
PID I Gain
P2285 Technology controller integral
action time
48
get, set
PID Up Limit
p2291 technology controller maximum
limiting
49
get, set
PID Down Limit
p2292 technology controller minimum
limiting
Communication
A.1 Communication
Industrial Security
Configuration Manual, 08/2017, A5E36912609A
195