Service and maintenance
8.2 Error messages
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
93
AutoId
status
OPC UA
status
AutoId
text
Error description
20
good
DEVICE_FAULT
Fault in power supply
The power supply is very close to the low limit.
20
good
DEVICE_FAULT
Antenna errors
•
The antenna or the antenna cable is defective.
•
Error in the connection to the reader; the reader is not
answering (in PROFIBUS operation).
–
The cable between the communications module and
reader is wired incorrectly or there is a cable break
–
The 24 V supply voltage is not connected or is turned off
or has failed briefly
–
Automatic fuse on the communications module has
blown
–
Hardware defective
–
Another reader is in the vicinity and is active
–
There is a reflecting metal surface in the vicinity that is
disrupting the antenna field
–
Execute "init_run" after correcting the error
--
--
--
The selected antenna is not enabled.
--
OpcUa_
BadInvalidS
tate
--
The command is not permitted in this status or is not supported.
Possible cause:
•
"INIT" was chained.
•
Command repetition was started without "Presence mode".
--
OpcUa_
BadOutOf
Range /
OpcUa_
Bad
Configurati
on
Error
--
No or bad configuration data/parameters were transferred.
Possible cause:
•
You are accessing a read point that is not configured.
--
BadInvalid
Argument
--
A parameter is missing.
--
BadInvalid
Argument
--
The parameter has an invalid format.
--
BadInvalid
Argument
--
The parameter type is invalid.
--
BadInvalid
Argument
--
Unknown parameter.
--
Bad
--
The command or the frame has an invalid format.