![Siemens SIMATIC RF360R Configuration Manual Download Page 11](http://html.mh-extra.com/html/siemens/simatic-rf360r/simatic-rf360r_configuration-manual_383253011.webp)
Security recommendations
2.1 Protocols
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
11
List of available protocols
All available protocols and their ports that are used with SIMATIC RF360R are listed below.
Table 2- 1
List of available protocols
Service/
Protocol
Protocol/
Port number
Preset port
status
Port
configurable
Port number
configurable
Authenticatio
n
Encryption
DHCP
UDP/68
Open
✓
--
--
--
PROFINET
UDP/34964
UDP/49152-
65535
Open
✓
--
--
--
HTTP
TCP/80
Closed
✓
--
--
--
HTTPS
TCP/443
Open
✓
--
✓
✓
NTP
UDP/123
Closed
✓
--
--
--
SNMP
UDP/161
Open
✓
--
--
--
EtherNet/IP
TCP/44818
UDP/44818
UDP/2222
Open
✓
--
--
--
OPC UA
TCP/4840
Open
✓
✓
✓
(when
configured)
✓
(when
configured)
XML
TCP/10001
Open
1)
✓
✓
--
--
Syslog
UDP/49152-
65535
Closed
✓
2)
--
--
--
1)
Applies to protocol number 10001, all others are closed.
2)
Only outgoing, when configured.
Explanation of the table:
•
Authentication
Specifies whether authentication of the communication partner takes place.
•
Encryption
Specifies whether the transfer is encrypted.