Configuring with the WBM
6.1 Starting WBM
SIMATIC RF360R
34
Configuration Manual, 03/2022, C79000-G8976-C629-02
You can call WBM using the versions of the following Web browsers current at the time of
publication of this manual: Microsoft Edge, Mozilla Firefox and Google Chrome. The user
interface of the WBM is designed for a screen resolution of at least 1366 x 768 pixels.
NOTICE
Aborting diagnostics due to open browser tabs
Note that some Web browsers stop updating Web pages when other tabs are in the
foreground. This behavior may cause ongoing diagnostics to be ended.
Procedure
Proceed as follows to start the WBM:
1.
Start your Web browser.
2.
Enter the IP address of the reader in the address field of your browser.
3.
Confirm your entry by pressing the <Enter> key.
Note
Updating HTTPS certificates
The first time you log on, the HTTPS certificate of the reader is shown as not secure. Note
that the certificate stored in the reader is only intended to ensure that the initial
connection establishment to the reader is encrypted. Confirm that the certificate is secure.
Then transfer your own, secure certificate to the reader.
Result: The WBM of the reader opens.
Alternatively, you can also open the WBM from the TIA Portal.
Note
The connection to the reader cannot be established
If no connection can be established to the reader, check the following points:
•
Make sure that all cables are correctly connected.
•
Ensure that the Ethernet connection has been established ("LK" LED lights up green).
•
Make sure that the reader has started up ("RUN" LED is lit/flashing green).
•
Check the IP addresses of the PC and the reader, as well as the subnet mask. Both IP
addresses must be located in the same subnet.
•
Make sure that the connection is not blocked by a firewall.
•
Check the connection between the PC and reader using a ping request.