SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
73
Programming
7
7.1
Programming via SIMATIC controller
This section is intended only for S7 users.
The reader is integrated in STEP 7 Basic / Professional from TIA Portal version V17 and can be
integrated in TIA Portal V16 via an HSP file. In both cases, you can program and configure the
reader using the "SIMATIC Ident" technology object. Alternatively, you can also program and
configure the reader using the Ident instructions. The Ident profile and the Ident blocks are
integrated in STEP 7 as of version V13.1.
In older TIA Portal versions (< V16), the reader can be integrated via a GSDML file. In this
case, you must use library version V4.0 of the Ident instructions to program and configure the
reader when operating via SIMATIC S7-1200/1500 controller.
You can find a detailed description of the Ident instructions (Ident profile and Ident blocks) in
the function manual "Ident profile and Ident blocks, standard function for Ident systems
https://support.industry.siemens.com/cs/ww/en/view/109793329
Note
Function block "FB 45" is not supported
Note that the "FB 45" function block is not supported by the reader.
7.2
Programming via XML
This section is intended only for XML users.
You can program the reader via the XML interface using XML commands. You can find
detailed information on this in the manual "XML programming for SIMATIC Ident
https://support.industry.siemens.com/cs/ww/en/view/109781631
7.3
Programming via OPC UA
This section is intended only for OPC UA users.
You can program the readers via the OPC UA interface using variables, events and methods.
You can find detailed information on this in the manual "OPC UA for SIMATIC Ident