Service and maintenance
8.2 Error messages
SIMATIC RF360R
84
Configuration Manual, 03/2022, C79000-G8976-C629-02
Flashin
g of the
reader
LED
Block (hex)
Error description
--
0xE1FE0400 Initialization error
Transponder is unable to execute the initialization command
Possible causes:
•
Transponder is defective.
--
0xE1FE0500 The transponder memory is full.
04
0xE1FE0600 RF300: Data storage was not completed correctly for the semaphore procedure.
11
0xE1FE0700 Password error
--
0xE1FE0900 The command is not supported by the transponder.
--
0xE1FE0A00 The transponder is read/write-protected.
--
0xE1FE8100 The transponder is not responding.
--
0xE1FE8200 The transponder password is incorrect. Access is denied.
--
0xE1FE8300 The verification of the written transponder data has failed.
Possible causes:
•
Transponder is defective.
•
Transponder is in the limit area.
--
0xE1FE8400 General transponder error
--
0xE1FE8500 The transponder has too little power to execute the command.
Possible causes:
•
Transponder is in the limit area.