Configuring with the WBM
6.3 The menu items of the WBM
SIMATIC RF360R
64
Configuration Manual, 03/2022, C79000-G8976-C629-02
All Syslog messages are displayed in the "Syslog logbook" menu item. This menu item
documents all safety-related access operations to the reader and performed actions. You can
find detailed information on the Syslog messages, their structure and contents in the section
"Syslog messages".
With the "Update" button, you can read in the entries from the reader again and update the
list. The displayed log entries contain 128 KB of data.
6.3.9
The "Edit transponder" menu item
You can read out and write transponder data with the "Edit transponder" menu item.
Figure 6-14 The "Edit transponder" menu item
In the "Read/write" area, you can read out and overwrite the memory areas. You can access
pre-defined addresses (tag fields). Using the parameters, you can adapt the memory area
manually.
Table 6- 22 Description of the parameters of the tag fields
Parameter
Description
Start address
Value of the start address of the data to be read/written.
Value range
0 ... 65535
Length
Number of bytes to be read/written starting at the start address.
Value range
1 ... 1024 bytes
Data
Input/output fields for the values (hexadecimal).
Possible characters
0 ... 9, A ... F
ASCII
Showing/hiding the ASCII view.
When the ASCII view is active, the data is shown additionally in ASCII
notation. You can edit the data both in the HEX format or in the ASCII
format.
You can choose between the two input modes "Overwrite" and "Insert".
Initialize data
Show/hide the view for initializing the data.
Using the initialization function, you can preset the data fields.
Next to the list of tag fields, the data of the selected memory area is displayed in hexadecimal
format.