Configuring with the WBM
6.3 The menu items of the WBM
SIMATIC RF360R
42
Configuration Manual, 03/2022, C79000-G8976-C629-02
Device clock
The device time according to ISO 8601 (UTC), as well as the calculated local time, is displayed
in this area. With the "Synchronize with PC" button, you can synchronize the displayed local
time with the time in your operating system.
Note
The device time always corresponds to UTC time (ISO 8601)
Note that the device time always corresponds to UTC time (ISO 8601) and cannot be adapted
to time zones. Clicking the button transfers the local time stored in your operating system to
the WBM. Because the time synchronized with the PC is lost when the power supply is
terminated, we recommend synchronizing the time with an NTP server.
Configuration display
A diagram of the reader is shown to the right of the areas. With the "Flash" check box, you
can have the LEDs of the reader flash. This enables you to quickly and easily identify the
reader.
6.3.2
The "Settings - General" menu item
The "Settings - General" menu item is divided into the following areas:
•
Log settings
•
Service logbook settings
Figure 6-4
The "Settings - General" menu item