Configuring with the WBM
6.3 The menu items of the WBM
SIMATIC RF360R
58
Configuration Manual, 03/2022, C79000-G8976-C629-02
Displayed parameters Description
Distance limiting
This parameter has no relevance for RF360R (Fixed value: 0).
Max. number of
transponders
Maximum number of transponders to be expected that may be located in
the antenna field at the same time. Due to single tag mode, RF360R may
have a maximum of one transponder in the antenna field.
Transponder type
Set transponder type profile
The following values are possible:
Value
Meaning
0x00
RF300 (RF3xxT)
0x01
ISO 15693 general
0x03
MDS D3xx, Infineon
0x04
MDS D4xx, Fujitsu - 2 KB
0x05
MDS D1xx, NXP
0x06
MDS D2xx, TI
0x08
MDS D5xx, Fujitsu - 8 KB
0x10
RF300 (RF3xxT)
0x11
General Mode
Antenna status
Status of the antenna
Presence check
Set presence check profile
Table 6- 18 Displayed parameters of the "Transponder status" area
Displayed parameters Description
UID
Unique identifier of the transponder
Transponder type
Transponder type (vendor, identification)
Version
Version of the transponder chip
Lock status of the OTP
area
Disabled blocks of the OTP area on the chip
Size of the user memory Memory size of the user memory in bytes
Size of a memory block Size of the memory blocks of the transponder chip
Number of memory
blocks
Number of memory blocks of the transponder chip
Measured value power
flux density
Radiant power that arrives at the transponder.
The lower the value, the more power the transponder receives.
Passive error counter
Number of passive errors which occurred
Active error counter
Number of errors which occurred
Sum of the signature and CRC errors
Presence counter