Configuring with the WBM
6.3 The menu items of the WBM
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
59
Error counter
The following error types are read and displayed:
Table 6- 19 Error types displayed in the "Error counter" area
Displayed error types Description
FZP
Passive error counter
This error counter is an indicator for a disturbed environment
(interferences).
ABZ
Abort counter
Counter for protocol errors on the air interface for which the transponder
aborted communication.
CFZ
Code error counter
Counter for disruptions or collisions on the air interface that caused
communication to be disturbed.
SFZ
Signature error counter
Counter for failed signature encryptions of written blocks of data. Only
relevant for the transponder type "RF300".
CRCFZ
CRC error counter
Counter for failed CRC checks
ASMFZ
Error counter for interface problems of the internal interface
Counter for errors on the serial interface
Signal strength
AMLI
AM power indicator
Received signal strength [dB] for which amplitude modulation with the
transponder was detected.
PMLI
PM power indicator
Received signal strength [dB] for which phase modulation with the
transponder was detected.
Note
Error counter readings
The displayed error counter readings are counted from the last restart of the reader or the last
manual reset of the error counter readings.