Service and maintenance
8.2 Error messages
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
87
Flashin
g of the
reader
LED
Block (hex)
Error description
--
0xE4FE8C00 •
Communication error between Ident profile and reader. Handshake error.
Possible causes / action to be taken:
–
The UDT of this device has been overwritten by other program sections.
–
Check the parameter settings of the device in the UDT.
–
Check the Ident profile command that causes this error.
–
After eliminating the error, execute the "INIT" command.
20
0xE4FE8D00 •
Communications error of the communications module/reader
Possible causes / action to be taken:
–
Connector contact problem on the communications module / reader
–
Hardware of the communications module/reader has a defect; →
Send in
communications module/reader for repair.
–
After eliminating the error, execute the "INIT" command.
•
Monitoring error of the communication module/reader
Possible causes / action to be taken:
–
Program execution error on the communications module / reader
–
Switch supply voltage to communications module/reader off and on again.
–
After eliminating the error, execute the "INIT" command.
•
Firmware error
Possible causes: The firmware update was not run completely.
--
0xE4FE8E00 The current command was aborted by the "WRITE-CONFIG" ("INIT" or "RESET") command for the
bus connector was pulled.
Possible causes:
•
Communication with the transponder was aborted by "INIT".
•
This error can only be reported if there is an "INIT" or "RESET".
--
0xE5FE0100 Incorrect sequence number order (SN) on the reader/communications module
--
0xE5FE0200 Incorrect sequence number order (SN) in the Ident profile
--
0xE5FE0400 Invalid data block number (DBN) on the reader/communications module
--
0xE5FE0500 Invalid data block number (DBN) in the Ident profile
--
0xE5FE0600 Invalid data block length (DBL) on the reader/communications module
--
0xE5FE0700 Invalid data block length (DBL) in the Ident profile