Service and maintenance
8.2 Error messages
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
85
Flashin
g of the
reader
LED
Block (hex)
Error description
06
0xE2FE0100 Field disturbance on reader
Possible causes:
•
The reader is receiving interference pulses from the environment.
–
External interference field. The interference field can be detected with the "inductive field
indicator" of the mobile reader.
–
The distance between two readers is too small and does not correspond to the
configuration guidelines.
–
The connecting cable to the reader is defective or too long or does not comply with the
specification.
•
Too many transmit errors
The transponder was unable to receive the command or the write data from the
communications module correctly even after several attempts.
–
The transponder is positioned exactly in the limit area of the transmission window.
–
Data transmission to the transponder is being affected by external interference.
•
CRC sending error
–
The transponder reports CRC errors frequently (transponder is positioned in the limit area
of the reader; transponder and/or reader has a hardware defect).
•
Only during initialization: CRC error on receipt of acknowledgment from transponder (cause
as for field interference on the reader).
•
When formatting, the transponder must be in the transmission window of the reader,
otherwise a timeout error will occur, in other words:
–
The transponder is located exactly in the limit range of the transmission window.
–
The transponder is defective and consumes too much power.
–
The EEPROM transponder was incorrectly configured by "FORMAT".
•
RF300: ECC error
The data cannot be read by the transponder.
Possible causes:
–
Transponder data has been lost (transponder defective).
–
The transponder was not initialized with the ECC driver.
–
The EEPROM memory of the transponder has reached its end of life and the data has
been lost.
–
The transponder left the antenna field during the write operation.
–
The command to the communications module was issued incorrectly.
--
0xE2FE0200 More transponders are located in the transmission window than can be processed at the same
time by the reader.
--
0xE2FE8100 There is no transponder with the required EPC ID/UID in the transmission window or there is no
transponder at all in the antenna field.
--
0xE2FE8200 The requested data is not available.
--
0xE2FE8300 CRC error in reader-transponder communication.
--
0xE2FE8400 The selected antenna is not enabled.
--
0xE2FE8500 The selected frequency is not enabled.
--
0xE2FE8600 The carrier signal is not activated.