4
Configuring......................................................................................................................................... 63
4.1
Configuring ET 200eco PN................................................................................................. 63
4.2
Configuring an IO-Link master........................................................................................... 64
4.2.1
Configuring the IO-Link Master 6ES7148-6JA00-0AB0.......................................................
4.2.2
Configuring the IO-Link Master 6ES7148-6JD00-0AB0.......................................................
4.3
Device names for ET 200eco PN........................................................................................
4.4
Ports of ET 200eco PN....................................................................................................... 68
4.5
Isochronous real-time communication..............................................................................
4.6
Prioritized startup.............................................................................................................
4.7
Device replacement without programming device............................................................. 69
4.8
Media redundancy............................................................................................................ 70
4.9
Reset to factory settings (PROFINET).................................................................................. 70
4.10
SNMP...............................................................................................................................
5
Commissioning................................................................................................................................... 72
5.1
Commissioning ET 200eco PN........................................................................................... 72
6
Maintenance....................................................................................................................................... 74
6.1
Replacing the fuse............................................................................................................
6.2
Online firmware update by means of STEP 7 Manager....................................................... 75
6.3
Acyclic data exchange with the IO-Link library................................................................... 76
6.4
Exchange object...............................................................................................................
6.5
Maintenance and repair.................................................................................................... 77
6.6
Cleaning the I/O device.....................................................................................................
7
Interrupt, error, and system messages............................................................................................... 78
7.1
Interrupts of ET 200eco PN................................................................................................ 78
7.2
Maintenance interrupts..................................................................................................... 78
7.3
Diagnostics by means of LED display.................................................................................
7.3.1
Diagnostics using the LED display on the I/O devices.......................................................... 80
7.3.2
Diagnostics using LED display on the IO-Link masters......................................................... 82
7.3.3
Diagnostics using the LED display at the voltage distributor............................................... 85
7.4
Diagnostics messages of the I/O devices............................................................................ 86
7.5
Diagnostics with STEP 7....................................................................................................
7.5.1
Reading diagnostics data................................................................................................... 86
7.5.2
Channel diagnostics.......................................................................................................... 86
7.5.3
Error classes for I/O devices............................................................................................... 87
7.5.4
STOP of the IO Controller and recovery of the IO Device..................................................... 91
8
Table of contents
ET 200eco PN
Operating Instructions, 06/2022, A5E01250250-AN
Summary of Contents for SIMATIC ET 200eco PN
Page 233: ...ET 200eco PN Operating Instructions 06 2022 A5E01250250 AN 234 Dimensional drawings C ...
Page 265: ...266 ET 200eco PN Operating Instructions 06 2022 A5E01250250 AN Open Source Software ...
Page 278: ...ET 200eco PN Operating Instructions 06 2022 A5E01250250 AN 279 Y Y cable 37 Index ...