Appendix
A.1 Measured variables
SENTRON PAC4200
194
Manual, 09/2008, A5E02316180B-01
Name
Abbrev.
DE + IEC
Abbrev.
EN + NAFTA
Unit
Displ
ay
LIM
SOURCE
Sliding Window Demand Total Reactive Power
(VARtot)
Q
tot sw-dmd
VAR
tot sw-dmd
VAR 7.3
ΣVARtot DMD
Sliding window demand of the total reactive power of the fundamental and harmonics (VARtot)
Maximum sliding window demand total reactive power
(VARtot)
Q
tot sw-dmd max
VAR
tot sw-dmd max
VAR 7.4
Maximum value of the sliding window demand of the total reactive power of the fundamental and
harmonics (VARtot)
Minimum sliding window demand total reactive power
(VARtot)
Q
tot sw-dmd min
VAR
tot sw-dmd min
VAR 7.5
Minimum value of the sliding window demand of the total reactive power of the fundamental and
harmonics (VARtot)
Sliding Window Demand Total Reactive Power
(VAR1)
Q
1 AVG
VAR
1 AVG
VAR 7.3
ΣVAR1 DMD
Sliding window demand of the total reactive power of the fundamental, measured according to VAR1
Maximum sliding window demand total reactive power
(VAR1)
Q
1 sw-dmd max
VAR
1 sw-dmd max
VAR 7.4
Maximum value of the sliding window demand of the total reactive power of the fundamental,
measured according to VAR1
Minimum sliding window demand total reactive power
(VAR1)
Q
1 sw-dmd min
VAR
1 sw-dmd min
VAR 7.5
Minimum value of the sliding window demand of the total reactive power of the fundamental,
measured according to VAR1
Sliding Window Demand Total Reactive Power
(VARn)
Q
n sw-dmd
VAR
n sw-dmd
VAR 7.3
ΣVARn DMD
Sliding window demand of the total reactive power of the harmonics, measured according to VARn
Maximum sliding window demand total reactive power
(VARn)
Q
n sw-dmd max
VAR
n sw-dmd max
VAR 7.4
Maximum value of the sliding window demand of the total reactive power of the harmonics, measured
according to VARn
Minimum sliding window demand total reactive power
(VARn)
Q
n sw-dmd min
VAR
n sw-dmd min
VAR 7.5
Minimum value of the sliding window demand of the total reactive power of the harmonics, measured
according to VARn
Sliding Window Demand Power Factor a
|PF
L1
|
sw-dmd
|PF
a
|
sw-dmd
–
8.3
PF DMD a
Sliding window demand of the power factor (arithmetic) a
Maximum sliding window demand power factor a
|PF
L1
|
sw-dmd
max
|PF
a
|
sw-dmd max
–
8.4
Maximum value of the sliding window demand of the power factor (arithmetic) a
Minimum sliding window demand power factor a
|PF
L1
|
sw-dmd min
|PF
a
|
sw-dmd min
–
8.5
Minimum value of the sliding window demand of the power factor (arithmetic) a
Sliding window demand power factor b
|PF
L2
|
sw-dmd
|PF
b
|
sw-dmd
–
8.3
PF DMD b
Sliding window demand of the power factor (arithmetic) b
Maximum sliding window demand power factor b
|PF
L2
|
sw-dmd
max
|PF
b
|
sw-dmd max
–
8.4
Maximum value of the sliding window demand of the power factor (arithmetic) b
Summary of Contents for SENTRON PAC4200
Page 66: ...Installation 5 4 Deinstalling SENTRON PAC4200 66 Manual 09 2008 A5E02316180B 01 ...
Page 118: ...Operator control 8 3 Special displays SENTRON PAC4200 118 Manual 09 2008 A5E02316180B 01 ...
Page 152: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 152 Manual 09 2008 A5E02316180B 01 ...
Page 168: ...Dimension drawings SENTRON PAC4200 168 Manual 09 2008 A5E02316180B 01 ...
Page 252: ...Index SENTRON PAC4200 252 Manual 09 2008 A5E02316180B 01 ...