2
07.96
Description
2-12
6ZB5 430–0BH02–1AA0
Siemens AG 1996 All Rights Reserved
SINUMERIK 805SM / 840C (BS)
Switch S2.1 = ON and S2.2 = OFF
Base address
S3.8
S3.7
S3.6
S3.5
S3.4
S3.3
S3.2
S3.1
0
ON
ON
ON
ON
ON
ON
x
x
16
ON
ON
ON
ON
ON
OFF
x
x
32
ON
ON
ON
ON
OFF
ON
x
x
48
ON
ON
ON
ON
OFF
OFF
x
x
54
ON
ON
ON
OFF
ON
ON
x
x
:
:
:
:
:
:
:
1008
OFF
OFF
OFF
OFF
OFF
OFF
x
x
Significance
2
9
=512
2
8
=256
2
7
=128
2
6
=64
2
5
=32
2
4
=16
x: Switch position of no significance
Switch S2.1 = ON and S2.2 = ON
Base address
S3.8
S3.7
S3.6
S3.5
S3.4
S3.3
S3.2
S3.1
0
ON
ON
ON
ON
ON
x
x
x
32
ON
ON
ON
ON
OFF
x
x
x
64
ON
ON
ON
OFF
ON
x
x
x
96
ON
ON
ON
OFF
OFF
x
x
x
:
:
:
:
:
:
992
OFF
OFF
OFF
OFF
OFF
x
x
x
Significance
2
9
=512
2
8
=256
2
7
=128
2
6
=64
2
5
=32
x: Switch position of no significance
Note
Base addresses are only possible for 4-byte, 8-byte, 16-byte or 32-byte steps
depending on the address range. For example, an address range of 32 bytes
permits only 0, 32, 64, 96 etc. as initial addresses.
Address range = 8 bytes and the base address is to be 24
⇒
S2.1 = OFF and S2.2 = ON
S3.8, S3.7, S3.6, S3.5, S3.4 = ON and S3.3, S3.2 = OFF
The assigned input and output area is from IB 24/QB 24 to IB 31/QB 31.
Base address for
16–byte address range
Base address for
32–byte address range
Example of address
setting
2.2 Hardware of the module 6FC5 012–0CA01–0AA0