07.96
Description
3-6
6ZB5 430–0BH02–1AA0
Siemens AG 1996 All Rights Reserved
SINUMERIK 805SM / 840C (BS)
((Einstellung des Adress.....etc. = wie S. 2.2, bitte übernehmen))
((Block 3))
Note
Address space of, for example, 4 bytes means that 4 input bytes and 4 output
bytes are available with the same base address.
((letzte Abschnitt wie S. 2.2, bitte übernehmen))
((S. 2–11))
Note:
The switches not required for 8, 16 and 32–bte address ranges are irrelevant
and any setting is permissible
((Rest der S. genau wie S. 2–3, bitten übernehmen))
((S. 2–12))
((genau wie S. 2–4, bitte übernehmen))
((S. 2–13))
Danger
An incorrect setting of the base address (e.g. dual address assignment or ad-
dress conflict with other I/O modules) results in ”wrong signal states” and can
cause an undefined behaviour of the control and the machine!
Switch S4.2
This switch must always be closed.
I/O ranges
In assigning the slaves, please note that different I/O ranges are available on
the SIROTEC ACR 20, SINUMERIK 805SM and SINUMERIK 840C control-
lers (see Section 2.1.1):
((S. 2–14))
2.2.2
Elements on the front plate
((ganze S. bis auf letzter Absatz wie alte Vorlage S. 2–5, aber mit den gelb
markierten Änderungen in wie in neue Vorlage S. 2–14 angegeben))
Interface for slave
Via the interface X111 (SUB–D, socket, 9–way), the slave is connected to the
SINEC L2–DP field bus.
((S. 2–15))
Note
TO connect up to the SINEC L2–DP field bus, the bus connectors with the
following order numbers are required:
Order number
Designation
SINEC L2 bus connector (degree of protection IP 20, without heavy–duty
thread socket)
SINEC L2 bus connector (degree of protection IP 20, with heavy–duty thread
socket)