07.96
Description
3-3
Siemens AG 1996 All Rights Reserved 6ZB5 430–0BH02–1AA0
SINUMERIK 805SM / 840C (BS)
Zehnerstelle
= Tens place
Hunderterstelle
= Hundreds place
Schalterstellung... = Switch position always down
grüne
= green
Statusanzeige
= Status display
rote
= red
Schnittstelle
= Interface
Schnittstelle X112 und LEDs... = Interface X112 and LEDs have no function if
they exist
DC/DC–Wandler DC/DC converter
Dual–Port–RAM = Dual port RAM
Busstecker
= Bus connector
((Unterschrift: ))
Fig. 2–1 Module IM 328–N with Order No.: 6FC5 012–0CA03–0AA0
((S. 2–2))
((Block 1))
Selecting the control system (S2.5, S2.6, S2.7 and S2.8)
The module can be used in the control systems listed. The control type must be
set with switches S2.5, S2.6, S2.7 and S2.8 as follows
((Block 2))
Note
The IM 328–N module can only be used for SINUMERIK 805SM in the cen-
tral controller.
((Block 3))
Note
Address space of, for example, 4 bytes means that 4 input bytes and 4 output
bytes are available with the same base address.
((S. 2–3))
Base address for 4–byte address range
Switch S2.1 = OFF and S2.2 = OFF
((Tabelle: ))
Base address
Significance
Base address for 8–byte address range
Switch S2.1 = OFF and S2.2 = ON
((Tabelle, wie oben))
x: Switch position of no significance