![Siemens 1PH818 Operating Instructions & Installation Instructions Download Page 94](http://html.mh-extra.com/html/siemens/1ph818/1ph818_operating-instructions-and-installation-instructions_378974094.webp)
8.3
Switching on the machine
● After starting the motor, observe it for a while to see if it is running smoothly and check the
monitoring devices.
● Monitor operation and the monitoring devices regularly and record the values you read off.
NOTICE
Speed monitoring
The motor is designed for a certain speed range.
If a motor is operated at impermissible speeds damage to the winding, bearings, or
complete destruction of the motor can be the result.
Ensure that the speeds specified on the rating plate are not exceeded by appropriately
configuring controller and speed monitoring components.
See also
NOTICE
Excessive machine temperature
If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine. This can result in material damage.
● Make sure that the anti-condensation heating is switched off before the machine is
switched on.
● Only operate anti-condensation heating when the machine is switched off.
8.4
Switching off water-cooled motors
● Switch off the cooling water supply for longer non-operational periods.
● When switching-off, also observe the converter operating instructions.
● If anti-condensation heating is available, switch it on.
8.5
Switching off force-ventilated motors
● Switch off the external fan during longer standstill periods.
Leave the fan on for approximately 30 minutes after switching off the motor to avoid
overheating of the motor.
● Follow the operating instructions of the converter.
Operation
8.5 Switching off force-ventilated motors
SIMOTICS M-1PH8 1PH818., 1PH822.
94
Operating Instructions 07/2016
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...