Bolted-on wheels and/or wings may only be replaced by authorised ZIEHL-ABEGG SE staff. The
manufacturer shall not be liable for damage caused through improper repair work.
•
The fan or motor is maintenance-free due to the use of ball bearings with
“
life-time lubrication
”
. At
the end of the grease service life (
Technical Data), it is necessary to change the bearing. The
grease service life may be lower than the theoretical value stated there (F
10h
) if particular operating
conditions such as vibrations, humidity or soiling in the bearing, unfavourable control modes, etc.
are present. Please consult our Service Department with regard to changing the bearing as for all
other damage (e.g. to the coil or electronics).
•
Regular inspection and possibly cleaning is necessary to prevent imbalance and blockage of the
condensation bores due to ingress of dirt.
•
When opening cable glands on the fan / motor, check the condition of the threaded connections
and seals. Always replace defective or brittle threaded connections and seals.
Information
Con
fi
rmation number for inquiries or in service cases
rating plate.
State the additionally engraved con
fi
rmation number (available depending on the motor build) if the
rating plate is no longer legible. This can be found under the af
fi
xed rating plate or on the stator
fl
ange
(in external rotor motors) depending on the motor size.
8.2
Cleaning
Danger due to electric current
Voltage supply for motor must be interrupted and secured against restoration!
Clean the fans`s
fl
ow area.
Attention!
•
Do not use any aggressive, paint solvent cleaning agents when cleaning.
•
Make sure that no water gets inside the motor and the electronics (e.g. by direct contact with seals
or motor openings), observe protection class (IP).
•
In case of improper cleaning work, no warranty is assumed regarding corrosion formation / paint
adhesion for unpainted / painted fans.
•
To avoid accumulation of moisture in the motor, the fan must be operated for at least 1 hour at 80%
to 100 % of the maximum speed before the cleaning process!
•
After the cleaning process, the fan must be operated for at least 2 hours at 80 to 100 % of the
maximum speed for drying purposes!
9
Enclosure
9.1
Technical data
Rated voltage range
(
Rating plate)
1 ~ 200...277 V, 50/60 Hz
Maximal line fuse
16 A
Max. load limit integral of cut-in current
approx.
2.0 A
2
s
Switching Freq.
16 kHz
Voltage supply for external devices
+10 V (-2 %), I
max
50 mA (short-circuit-proof)
Analogue input
“
E1
”
Input resistance: R
i
> 100 k
Ω
Speci
fi
cation speed setting signal PWM
Voltage: 15...28 V DC
Switching frequency: 1...10 kHz
On-off ratio: 0...100 %
Digital input
“
D1
”
Input resistance: R
i
approx. 2 k
Ω
Voltage range high level: 7.1...19 V DC
Voltage range low level: 0....2.7 V DC
Contact rating of the internal relay
“
K1
”
AC 250 V 2 A
Assembly instructions
ECblue
Enclosure
L-BAL-F065-GB 1617 Index 004
Part.-No. 00702801-GB
23/28
187
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...