Figure 4-3
Air guidance from the NDE to the DE (schematic representation, type 1PH828.) for IP55
External fan
The code for the external fan is at the eleventh position of the order number. The order number
– and therefore the installed external fan type – is specified on the rating plate.
Machines with pipe connection
You must mount and connect pipes and a fan of suitable type and dimensioning to machines
that are intended for the connection of pipes and/or for operation with an external fan.
Please observe the following when connecting pipes:
● Additional pressure drop in the system.
● Shipping covers on the ventilation openings must have been removed.
For machines with a pipe connection, the potential pressure drop inside the machine is given
in the following table:
Table 4-2
Pressure drop in motors with pipe connection
Type
Degree of pro‐
tection
Volume flow
Pressure drop
Flow resistance
1PH818.
IP23
0.21 m
3
/s
450 Pa
10204 Ns
2
/m
8
IP55
0.17 m
3
/s
550 Pa
19030 Ns
2
/m
8
1PH822.
IP23
0.33 m
3
/s
600 Pa
5510 Ns
2
/m
8
IP55
0.31 m
3
/s
650 Pa
6760 Ns
2
/m
8
1PH828.
IP23
0.52 m
3
/s
600 Pa
2220 Ns
2
/m
8
IP55
0.42 m
3
/s
600 Pa
3400 Ns
2
/m
8
Preparations for use
4.4 Ensuring cooling
SIMOTICS M-1PH8 1PH818., 1PH822.
32
Operating Instructions 07/2016
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...