greases significantly exceed the requirements according to DIN 51825 and ISO 6743‑9,
therefore permitting the specified relubrication intervals.
Initial lubrication
The following greases are used for initial lubrication of the bearings in the factory.
● Standard version: ESSO / Unirex N3
● "Performance" version: Lubcon / Sintono GPE702
Grease selection criteria
The following greases are permissible for standard applications without any special
requirements:
● High quality ISO‑L‑X BDEA3 greases according to ISO 6743-9
● K3N‑20 greases according to DIN 51825 with lithium soap as thickener and an upper
service temperature of at least +140 °C / +284 °F.
When selecting the lubricating grease, ensure that the technical data of the grease is suitable
for the application.
The lubricating grease must satisfy the criteria listed in the table below and must match the
operating conditions. If different special lubricating greases are stated on the lubricant plate,
then different criteria apply.
Table 9-3
Criteria for selecting roller bearing greases
Criteria
Standard
Property, characteristic value
Unit
Type of base oil
-
Mineral oil
-
Thickener
-
Lithium
-
Consistency according to NLGI class DIN 51818
● 3 for vertical and horizontal types of construction
● 2 alternatively for horizontal type of construction
with reduced lubrication interval
-
Worked penetration
DIN ISO 2137
220–295
0.1 mm
Operating temperature range
-
At least -20 °C ... +140 °C
°C
Dropping point
DIN ISO 2176
At least +200 °C
°C
Basic oil viscosity
DIN 51562-1
● Approx. 100 mm²/s at 40° C
● Approx. 10 mm²/s at 100 °C
mm²/s
Additive
-
● Antioxidation (AO), Anti-Wear (AW)
● No solid lubricants
● Alternatively: Extreme-Pressure (EP) only after
consultation with grease and bearing
manufacturers
-
FE9 test: A/1500/6000
DIN 51821-1/-2
F10 ≥ 50 h at +140 °C
F50 ≥ 100 h at +140 °C
h
Behavior with respect to water
DIN 51807
0 or 1 at a test temperature of +90 °C
-
Corrosive effect on copper
DIN 51811
0 or 1 at a test temperature of +140 °C
Corr.°
Resistance to corrosion (EMCOR)
DIN 51802 /
ISO 11007
0 - 0 (0 - 1, permissible for special greases)
Corr.°
Maintenance
9.2 Inspection and maintenance
SIMOTICS M-1PH8 1PH818., 1PH822.
106
Operating Instructions 07/2016
Summary of Contents for 1PH818
Page 2: ...18 07 2016 14 04 V14 00 ...
Page 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Page 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Page 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Page 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Page 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...