Normal operation
Measure the normal operating temperature of the bearings T
op
at the installation location in
°C. Set the values for shutdown and warning corresponding to the operating temperature T
op
.
Table 7-2
Set values for monitoring the bearing temperatures
Set value
Temperature
Alarm
T
operation
+ 5 K ≤ 115 °C
Shutting down
T
operation
+ 10 K ≤ 120 °C
Commissioning
7.7 Set values for monitoring the bearing temperature (optional)
SIMOTICS M-1PH8 1PH818., 1PH822.
90
Operating Instructions 07/2016