MX3500N TRANSFER SECTION L – 7
o. Cleaner seal
p. Cleaner seal R
1) Remove the primary trasnfer unit.
2) Remove the cleaner unit.
3) Remove the cleaner seal (A) and the cleaner seal R (B).
* When attaching the seals, position the seals within the spec-
ified ranges, referring to the reference lines as indicated
below.
q. Transfer toner reception seal
1) Remove the primary trasnfer unit.
2) Remove the cleaner unit.
3) Remove the transfer toner reception seal.
* When attaching the transfer toner reception seal, position
the seal within the specified ranges, referring to the refer-
ence lines as indicated below.
r. Waste toner screw
1)
Remove the primary trasnfer unit.
2)
Remove the cleaner unit.
3)
Remove the screw, the cleaner cover, and the waste toner
shutter.
4)
Remove the gear on the rear side. Remove the resin ring, the
bearing, and the transfer waste toner pipe. Remove the waste
toner screw.
* Attach the C-J mixing sheet to the attachment reference.
(2) Others
a. Transfer belt separation CL detection
b. Transfer belt separation BK detection
1)
Remove the primary trasnfer unit.
2)
Remove the developing unit.
3)
Remove the drum unit.
4)
Check the transfer belt separation CL detection (A) and the
transfer belt separation BK detection (B).
A
B
Reference line
Reference line
0 - 0.3mm
0 - 0.3mm
0 - 0.3mm
Reference line
Reference line
0 - 0.3mm
0 - 0.3mm
Reference line
0.5mm
0
A
B