MX3500N SIMULATION 7 – 54
<Set range and default value of each setup>
* On adjustment values
Each temperature correction value
→
Temperature 1
°
C change
by 1 count
Each paper exit count
→
1 sheet by 1 count
Each cool-down time
→
1s change by 1 count
<Code descriptions of the above list>
43-31
Purpose
Operation check
Function (Purpose)
Used to check the operation of the fusing
web cleaning motor.
Section
Fusing
Item
Operation
Operation/Procedure
1)
Remove the fusing unit.
2)
Enter the simulation mode with the door open, and press
[EXECUTE] button.
3)
Perform the fusing web cleaning motor drive (continuous rota-
tion for 10 sec). After completion, "COMPLETE" is displayed.
Item
Display items
Item descriptions
Set
range
Default
value
A
NN_120_ WUP_HL_UM&HL_E
WARMUP end temperature
correction value
120
°
C or below when turning
on the power under NN
environment
Item Sim. 43-1-A, C
1 to 99
50
B
NN_120_WUP_HL_LM
Item Sim. 43-1-B
1 to 99
50
C
LL_120_ WUP_HL_UM&HL_E
120
°
C or below when turning
on the power under LL
environment
Item Sim. 43-20-A, C
1 to 99
55
D
LL_120_WUP_HL_LM
Item Sim. 43-20-B
1 to 99
60
E
HH_120_ WUP_HL_UM&HL_E
120
°
C or below when turning
on the power under HH
environment
Item Sim. 43-21-A, C
1 to 99
50
F
HH_120_WUP_HL_LM
Item Sim. 43-21-B
1 to 99
50
G
ON_120_WUP_HL_UM
Temperature correction value
immediately after completion of
warm-up and during continuation
of temperature correction
120
°
C or below when turning
on the power
Item Sim. 43-1-A
1 to 99
60
H
ON 120 WUP HL_E
Item Sim. 43-1-C
1 to 99
55
I
NN_120_ FUS_DUP_HL_UM & HL_E
Fusing temperature correction
value
120
°
C or below when turning
on the power under NN
environment
Item Sim. 43-4-A, C,
E, G
1 to 99
55
J
NN_120_ FUS_DUP_HL_LM
Item Sim. 43-4-B, F
1 to 99
50
K
LL_120_ FUS_DUP_HL_UM&HL_E
120
°
C or below when turning
on the power under LL
environment
Item Sim. 43-22-A,
C, E, G
1 to 99
60
L
LL_120_ FUS_DUP_HL_LM
Item Sim. 43-22-B, F
1 to 99
50
M
HH_120_ FUS_DUP_HL_UM&HL_E
120
°
C or below when turning
on the power under HH
environment
Item Sim. 43-23-A,
C, E, G
1 to 99
50
N
HH_120_ FUS_DUP_HL_LM
Item Sim. 43-23-B, F
1 to 99
50
O
NN_120_ FUS_DUP_CNT
Fusing duplex paper exit count
Applicable number of sheets for SIM43-24-I, J (NN
environment)
1 to 60
5
P
LL_120_ FUS_DUP_CNT
Applicable number of sheets for SIM43-24-K, L (LL
environment)
1 to 60
10
Q
HH_120_ FUS_DUP_CNT
Applicable number of sheets for SIM43-24-M, N (HH
environment)
1 to 60
5
R
COOL_DOWN_HEAVY
Cool-down time
Cool-down time (Heavy paper
→
Ready)
1 to 60
15
S
COOL_DOWN_OHP
Cool-down time (OHP
→
Ready)
1 to 60
30
T
COOL_DOWN_DEVELOP
Cool-down time (Envelope
→
Ready)
1 to 60
40
U
WUP DUP TIME
Temperature correction
continuation time immediately
after completion of warm-up
Applicable time for SIM43-24-G, H (Timer from
completion of ready)
0 to 255
120
V
FUS MOTOR
Fusing web motor operation
interval
Web motor operation interval
1 to 20
6
TH_UM
Fusing upper thermister MAIN center
TH_LM
Fusing lower thermister MAIN
TH_E
Fusing thermister external
HL_UM
Heater lamp upper MAIN
HL_LM
Heater lamp lower MAIN
HL_E
Heater lamp external
0
A:
A
㧦
50
B
㧦
50
C
㧦
50
D
㧦
50
㧧
NN_120_ WUP_HL_UM&HL_E
㧧
NN_120_WUP_HL_LM
㧧
LL_120_ WUP_HL_UM
㧒
HL_E
㧧
LL_120_WUP_HL_LM
SIMULATION
NO.43.-24
FUSER
TEMP
RESET
50
㨇
1
㨪
99
㨉
OK
TEST
CLOSE
SIMULATION NO.43-31
TEST
FUSER
WEB
CLEANING
CHECK
1/1
0
CLOSE
EXECUTE