MX3500N SIMULATION 7 – 50
If there is no item over [
↓
], the display grays out and the
operation is invalid.
3) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4) When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [
↑
], [
↓
], [COLOR], or [BLACK] key is pressed, the cur-
rent set value is saved to EEPROM and RAM.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Correction value: (–49 to +49) Input value: Actually entered value
(1 to 99)
<List of setting parameters>
*
1
: MX-4500N/4501N only
* WARMUP END TIME LL
→
1s change by 1 count
The other correction values
→
1
°
C change by 1 count
<Code descriptions in the above list>
43-21
Purpose
Setting
Function (Purpose)
Used to perform correction of high temper-
ature and high humidity (H/H) environment
for the fusing temperature setting 1 (SIM
43-01) for each paper.
Section
Fusing
Item
Operation
Operation/Procedure
1)
When the machine enters SIM 43-21, the following screen is
displayed. (The current set value is displayed.)
2)
Select the set item with [
↑
] and [
↓
] buttons.
Correction value
–49
–25
–5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display item
Item content
Set
range
Default
value
A
HL_UM
READY LL
Correction value for TH_UM
set value in Ready standby
under LL environment
1 to 99
55
B
HL_LM
READY LL
Correction value for TH_LM
set value in Ready standby
under LL environment
1 to 99
55
C
HL_E READY
LL
Correction value for TH_E
set value in Ready standby
under LL environment
1 to 99
55
D
HL_UM PLAIN
BW LL
Correction value for BW
plain paper TH_UM set
value under LL environment
1 to 99
55
E
HL_LM PLAIN
BW LL
Correction value for BW
plain paper TH_LM set
value under LL environment
1 to 99
55
F
HL_E PLAIN
BW LL
Correction value for BW
plain paper TH_E set value
under LL environment
1 to 99
55
G
HL_UM PLAIN
CL LL
Correction value for COLOR
plain paper TH_UM set
value under LL environment
1 to 99
55
H
HL_LM PLAIN
CL LL
Correction value for COLOR
plain paper TH_LM set
value under LL environment
1 to 99
55
I
HL_E PLAIN
CL LL
Correction value for COLOR
plain paper TH_E set value
under LL environment
1 to 99
55
J
WARMUP
FUMON
HL_UM T LL
Correction value for fusing
motor front rotation start
TH_UM set value under LL
environment
1 to 99
60
K
WARMUP
FUMOFF
HL_LM T LL
Correction value for fusing
motor front rotation start
TH_LM set value under LL
environment
1 to 99
60
L
WARMUP
END TIME LL
Correction value for WARM
UP complete time under LL
environment
1 to 99
80
M
HL_UM
HEAVY LL
Correction value for heavy
paper TH_UM set value
under LL environment
1 to 99
60
N
HL_LM HEAVY
LL
Correction value for heavy
paper TH_LM set value
under LL environment
1 to 99
60
O
HL_E HEAVY
LL
Correction value for heavy
paper TH_E set value under
LL environment
1 to 99
60
P
HL_UM OHP
LL
Correction value for OHP
TH_UM set value under LL
environment
1 to 99
60
Q
HL_LM OHP
LL
Correction value for OHP
TH_LM set value under LL
environment
1 to 99
60
R
HL_E OHP LL
Correction value for OHP
TH_E set value under LL
environment
1 to 99
60
S
HL_UM
ENVELOPE LL
Correction value for
ENVELOPE TH_UM set
value under LL environment
1 to 99
60
T
HL_LM
ENVELOPE LL
Correction value for
ENVELOPE TH_LM set
value under LL environment
1 to 99
60
U
HL_E
ENVELOPE LL
Correction value for
ENVELOPE TH_E set value
under LL environment
1 to 99
60
V
HL_UM E-
STAR LL
Correction value for
preheating TH_UM set
value under LL environment
1 to 99
60
W
HL_UM PRE-
JOB LL
Correction value for TH_UM
set value when resetting
from preheating under LL
environment
1 to 99
60
X
HL_E PRE-
JOB LL
Correction value for TH_E
set value when resetting
from preheating under LL
environment
1 to 99
60
Y
HL_UM
PLAIN-45 BW
*
1
Correction value for BW
high speed plain paper
TH_UM set value under LL
environment
1 to 99
55
Z
HL_LM PLAIN-
45 BW *
1
Correction value for BW
high speed plain paper
TH_LM set value under LL
environment
1 to 99
55
AA
HL_E PLAIN-
45 BW *
1
Correction value for BW
high speed plain paper
TH_E set value under LL
environment
1 to 99
55
TH_UM
Fusing upper thermister main
TH_LM
Fusing lower thermister main
TH_E
Fusing upper thermister external
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_E
Heater lamp external
Item
Display item
Item content
Set
range
Default
value
0
A:
A
㧦
60
㧧
HL_UM
READY LL
SIMULATION
NO.43-20
FUSER
TEMP
ADJUSTMENT
(LL)
60
㨇
1
㨪
99
㨉
OK
TEST
B
㧦
60
㧧
HL_LM
READY LL
C
㧦
60
㧧
HL_E
READY LL
D
㧦
60
㧧
HL_UM
PLAIN BW LL
CLOSE