MX3500N SELF DIAG AND TROUBLE CODE 8 – 11
E7-09
Local memory combination error
* When the following combination (E7-09) where operation is not
performed properly is used. Local memory (slot 3, slot 4) combi-
nation
E7-10
Shading trouble (Black correction)
E7-11
Shading trouble (White correction)
E7-14
SCAN-ASIC trouble
E7-20
LSU BD detection trouble
E7-21
LSU LD deterioration trouble
Trouble content
Local memory slot combination error
Section
MFP
Case 1
Cause
DIMM of other than 256MB is installed to the default
slot.
Check
and
remedy
Check the combination of installed DIMM.
Case 2
Cause
DIMM of other than 256MB is installed to the
expansion slot.
Check
and
remedy
Check the combination of installed DIMM.
No.
Local memory
Operation guarantee
When turning
on the power
Slot 4
(Inside)
Slot 3
(Outside)
Hard
Soft
1
–
–
✕
✕
E7-09
2
256MB
–
{
{
Normal operation
3
512MB
–
{
✕
E7-09
4
256MB
256MB
{
✕
E7-09
5
512MB
256MB
{
✕
E7-09
6
256MB
512MB
{
{
Normal operation
7
512MB
512MB
{
✕
E7-09
8
–
256MB
✕
✕
E7-09
9
–
512MB
✕
✕
E7-09
Trouble content
CCD black scan level abnormality when the copy lamp
is turned off.
Section
Scanner
Case 1
Cause
Installation error of the CCD unit flat cable
Check
and
remedy
Check the installing state of the flat cable to the CCD
unit.
Case 2
Cause
CCD unit abnormality
Check
and
remedy
Check the CCD unit.
Case 3
Cause
SCU PWB abnormality
Check
and
remedy
Check the SCU PWB.
Trouble content
CCD white scan level abnormality when the copy lamp
is on.
Section
Scanner
Case 1
Cause
Installation error of the CCD unit flat cable
Check
and
remedy
Check the installing state of the flat cable to the CCD
unit.
Case 2
Cause
Dirt on the mirror, the lens, or the reference white
plate.
Check
and
remedy
Clean the mirror, the lens, or the reference white plate.
Case 3
Cause
Copy lamp lighting trouble
Check
and
remedy
Check the installing state of the flat cable to the copy
lamp unit.
Case 4
Cause
CCD unit abnormality
Check
and
remedy
Check the CCD unit.
Case 5
Cause
SCU PWB abnormality
Check
and
remedy
Check the SCU PWB.
Trouble content
Written register value cannot be read correctly
Section
Scanner
Case 1
Cause
SCU PWB abnormality
Check
and
remedy
Check the SCU PWB.
Trouble content
LSU BD signal is not detected.
Section
PCU
Case 1
Cause
Disconnection or improper connection of harness and
connector between LD/BD PWB and LSUcnt PWB
Check
and
remedy
Check connection of the harness of each PWB inside
the LSU.
Case 2
Cause
1)
Optical axis shift
2)
BK laser deterioration, power reduction
3)
BD PWB trouble
Check
and
remedy
1)
Use SIM61-1 to check the LSU operation.
2)
Replace the LSUcnt/BD PWB.
3)
If the trouble cannot be removed by the above 1)
to 2), replace the LSU.
Trouble content
The color laser does not light up normally.
Section
PCU
Case 1
Cause
Disconnection or improper connection of harness and
connector between LD PWB and LSUcnt PWB
Check
and
remedy
Check connection of the harness of each PWB inside
the LSU.
Case 2
Cause
Y/M/C laser deterioration
Check
and
remedy
1)
Use SIM61-1 to check the LSU operation.
2)
Replace the LSUcnt PWB.
3)
If the trouble cannot be removed by the above 1)
to 2), replace the LSU.
Summary of Contents for MX 3501N - Color Laser - Copier
Page 64: ...MX3500N ADJUSTMENTS 6 19 E F Yellow C D Magenta A B Cyan ...
Page 390: ...MX3500N PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Page 444: ...Memo ...