MX3500N SIMULATION 7 – 51
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
3) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4) When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [
↑
], [
↓
], [COLOR], or [BLACK] key is pressed, the current
set value is saved to EEPROM and RAM.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Set value: Value to be set (–49 to +49), Input value: Actual input
(1 to 99)
<List of setting parameters>
*
1
: MX-4500N/4501N only
* WARMUP END TIME HH
→
1s change by 1 count
The other correction values
→
1
°
C change by 1 count
<Code descriptions in the above list>
Set value
–49
–25
–5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Item display
Content of item
Set
range
Default
value
A
HL_UM
READY HH
Correction value for TH_UM
set value in READY
standby under HH
environment
1 to 99
50
B
HL_LM READY
HH
Correction value for TH_LM
set value in READY
standby under HH
environment
1 to 99
50
C
HL_E READY
HH
Correction value for TH_E
set value in READY
standby under HH
environment
1 to 99
50
D
HL_UM PLAIN
BW HH
Correction value for BW
plain paper TH_UM set
value under HH
environment
1 to 99
50
E
HL_LM PLAIN
BW HH
Correction value for BW
plain paper TH_LM set
value under HH
environment
1 to 99
50
F
HL_E PLAIN
BW HH
Correction value for BW
plain paper TH_E set value
under HH environment
1 to 99
50
G
HL_UM PLAIN
CL HH
Correction value for
COLOR plain paper TH_UM
set value under HH
environment
1 to 99
50
H
HL_LM PLAIN
CL HH
Correction value for
COLOR plain paper TH_LM
set value under HH
environment
1 to 99
50
I
HL_E PLAIN
CL HH
Correction value for
COLOR plain paper TH_E
set value under HH
environment
1 to 99
50
J
WARMUP
FUMON
HL_UM T HH
Correction value for fusing
motor front rotation start
TH_UM set value under HH
environment
1 to 99
50
K
WARMUP
FUMOFF
HL_LM T HH
Correction value for fusing
motor front rotation end
TH_LM set value under HH
environment
1 to 99
50
L
WARMUP END
TIME HH
Correction value for WARM
UP end time under HH
environment
1 to 99
50
M
HL_UM HEAVY
HH
Correction value for heavy
paper TH_UM set value
under HH environment
1 to 99
50
N
HL_LM HEAVY
HH
Correction value for heavy
paper TH_LM set value
under HH environment
1 to 99
50
O
HL_E HEAVY
HH
Correction value for heavy
paper TH_E set value under
HH environment
1 to 99
50
P
HL_UM OHP
HH
Correction value for OHP
TH_UM set value under HH
environment
1 to 99
50
Q
HL_LM OHP
HH
Correction value for OHP
TH_LM set value under HH
environment
1 to 99
50
R
HL_E OHP HH
Correction value for OHP
TH_E set value under HH
environment
1 to 99
50
S
HL_UM
ENVELOPE
HH
Correction value for
ENVELOPE TH_UM set
value under HH
environment
1 to 99
50
T
HL_LM
ENVELOPE
HH
Correction value for
ENVELOPE TH_LM set
value under HH
environment
1 to 99
50
U
HL_E
ENVELOPE
HH
Correction value for
ENVELOPE TH_E set value
under HH environment
1 to 99
50
V
HL_UM E-
STAR HH
Correction value for
preheating TH_UM set
value under HH
environment
1 to 99
50
W
HL_UM PRE-
JOB HH
Correction value for TH_UM
set value when resetting
from preheating under HH
environment
1 to 99
50
X
HL_E PRE-
JOB HH
Correction value for TH_E
set value when resetting
from preheating under HH
environment
1 to 99
50
Y
HL_UM PLAIN-
45 BW *
1
Correction value for BW
high speed plain paper
TH_UM set value under LL
environment
1 to 99
50
Z
HL_LM PLAIN-
45 BW *
1
Correction value for BW
high speed plain paper
TH_LM set value under LL
environment
1 to 99
50
AA
HL_E PLAIN-
45 BW *
1
Correction value for BW
high speed plain paper
TH_E set value under LL
environment
1 to 99
50
TH_UM
Fusing upper thermister main
TH_LM
Fusing lower thermister main
TH_E
Fusing upper thermister external
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_E
Heater lamp external
Item
Item display
Content of item
Set
range
Default
value
Summary of Contents for MX 3501N - Color Laser - Copier
Page 64: ...MX3500N ADJUSTMENTS 6 19 E F Yellow C D Magenta A B Cyan ...
Page 390: ...MX3500N PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Page 444: ...Memo ...
Page 445: ...Memo ...