MX3500N SIMULATION 7 – 127
<Display item and description> (MX-3501N/4501N)
* On the screen, [G] is pressed.
63-2
Purpose
Adjustment
Function (Purpose)
Used to execute shading forcibly. (MX-
3500N/4500N)
Section
Scanner
Item
Operation
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted and
shading is started.
* During execution, "SHADING EXECUTING..." is displayed.
* When [EXECUTE] button is pressed during execution, the
operation is interrupted.
* When shading is completed normally, [EXECUTE] button
returns to the normal display and "COMPLETED" is dis-
played.
* When [SYSTEM SETTINGS] key is pressed during other
than printing, the display returns to the sub number entry
screen.
63-2
Purpose
Adjustment
Function (Purpose)
Used to execute shading forcibly. (MX-
3501N/4501N)
Section
Scanner
Item
Operation
Operation/Procedure
1)
Select [OC SHADING], [DSPF SHADING].
2)
When [EXECUTE] button is pressed, it is highlighted and
shading is started.
* During execution, "SHADING EXECUTING..." is displayed.
* When [EXECUTE] button is pressed during execution, the
operation is interrupted.
* When shading is completed normally, [EXECUTE] button
returns to the normal display and "COMPLETED" is dis-
played.
* When [SYSTEM SETTINGS] key is pressed during other
than printing, the display returns to the sub number entry
screen.
RSPF WHITE
LEVEL 2ND
Second and later scan,
RSPF white reference
level
Button
Display item
Description
Remark
OC
GAIN ODD
Gain adjustment value
(ODD)
GAIN EVEN
Gain adjustment value
(EVEN)
OFFSET ODD
Offset value (ODD)
OFFSET EVEN
Offset value (EVEN)
SMP AVE ODD
Reference plat
sampling average
value (ODD)
SMP AVE
EVEN
Reference plat
sampling average
value (EVEN)
TARGET
VALUE
Target value
BLACK LEVEL
Black output level
ERROR CODE
Error code (0, 1 to 4)
0: No error
1: STAGE1. Over
the loop number
2: STAGE2. The
target value is less
than the specified
level.
3: STAGE3. The
gain set value is
negative.
4: END is not
asserted.
DSPF FACE
WHITE LEVEL
1ST
First scan, DSPF front
surface white
reference level
DSPF FACE
WHITE LEVEL
2ND
Second and later scan,
DSPF front surface
white reference level
DSPF
GAIN ODD
Gain adjustment value
(ODD)
GAIN_EVEN
Gain adjustment value
(EVEN)
OFFSET ODD
Offset value (ODD)
OFFSET EVEN
Offset value (EVEN)
SMP AVE ODD
Reference plat
sampling average
value (ODD)
SMP AVE
EVEN
Reference plat
sampling average
value (EVEN)
TARGET
VALUE
Target value
BLACK LEVEL
Black output level
ERROR CODE
Error code (0, 1 to 4)
0: No error
1: STAGE1. Over
the loop number
2: STAGE2. The
target value is less
than the specified
level.
3: STAGE3. The
gain set value is
negative.
4: END is not
asserted.
DSPF BACK
WHITE LEVEL
1ST
First scan, DSPF back
surface white
reference level
DSPF BACK
WHITE LEVEL
2ND
Second and later scan,
DSPF back surface
white reference level
Display item
Description
Remark
0
OFFSET ODD
0
:
SIMULATION
NO.63
̆
01
TEST
SHADING
DATA
DISPLAY
CLOSE
1/3
GAIN
ODD
147
:
GAIN
EVEN
143
:
OFFSET EVEN
0
:
B
G
R
SIMULATION
NO.63
̆
02
TEST
SHADING
EXECUTION
EXECUTE
0
CLOSE
PRESS
[EXECUTE]
TO
SHADING
START
Summary of Contents for MX 3501N - Color Laser - Copier
Page 64: ...MX3500N ADJUSTMENTS 6 19 E F Yellow C D Magenta A B Cyan ...
Page 390: ...MX3500N PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Page 444: ...Memo ...
Page 445: ...Memo ...