MX3500N SIMULATION 7 – 107
(Initial screen or when in normal end)
(Adjustment screen)
(Error end screen)
Main scan
adjustment
error
50
MAIN BLACK FRONT
Number error main scan BLACK F
The number of pitch data is not the specified number.
51
MAIN BLACK FRONT
Pitch error main scan BLACK F
The pitch data is not in the specified allowable range.
55
MAIN BLACK REAR
Number error main scan BLACK R
The number of pitch data is not in the specified range.
56
MAIN BLACK REAR
Pitch error main scan BLACK R
The pitch data is not in the specified allowable range.
60
MAIN CYAN FRONT
Number error main scan CYAN F
The number of pitch data is not the specified number.
61
MAIN CYAN FRONT
Pitch error main scan CYAN F
The pitch data is not in the specified allowable range.
62
MAIN CYAN FRONT
Adjustment value error main scan
CYAN F
The calculation result value is not in the specified allowable
range.
63
MAIN CYAN FRONT
Result value error main scan CYAN
F
The variation of the calculation result value is over the
specified allowable range.
65
MAIN CYAN REAR
Number error main scan CYAN R
The number of pitch data is not the specified number.
66
MAIN CYAN REAR
Pitch error main scan CYAN R
The pitch data is not in the specified allowable range.
67
MAIN CYAN REAR
Adjustment value error main scan
CYAN R
The calculation result value is not in the specified allowable
range.
68
MAIN CYAN REAR
Result value error main scan CYAN
R
The variation of the calculation result value is over the
specified allowable range.
70
MAIN MAGENTA FRONT
Number error main scan MAGENTA
F
The number of pitch data is not the specified number.
71
MAIN MAGENTA FRONT
Pitch error main scan MAGENTA F
The pitch data is not in the specified allowable range.
72
MAIN MAGENTA FRONT
Adjustment value error main scan
MAGENTA F
The calculation result value is not in the specified allowable
range.
Main scan
adjustment
error
73
MAIN MAGENTA FRONT
Result value error main scan
MAGENTA F
The variation of the calculation result value is over the
specified allowable range.
75
MAIN MAGENTA REAR
Number error main scan MAGENTA
R
The number of pitch data is not the specified number.
76
MAIN MAGENTA REAR
Pitch error main scan MAGENTA R
The pitch data is not in the specified allowable range.
77
MAIN MAGENTA REAR
Adjustment value error main scan
MAGENTA R
The calculation result value is not in the specified allowable
range.
78
MAIN MAGENTA REAR
Result value error main scan
MAGENTA R
The variation of the calculation result value is over the
specified allowable range.
80
MAIN YELLOW FRONT
Number error main scan YELLOW
F
The number of pitch data is not the specified number.
81
MAIN YELLOW FRONT
Pitch error main scan YELLOW F
The pitch data is not in the specified allowable range.
82
MAIN YELLOW FRONT
Adjustment value error main scan
YELLOW F
The calculation result value is not in the specified allowable
range.
83
MAIN YELLOW FRONT
Result value error main scan
YELLOW F
The variation of the calculation result value is over the
specified allowable range.
85
MAIN YELLOW REAR
Number error main scan YELLOW
R
The number of pitch data is not the specified number.
86
MAIN YELLOW REAR
Pitch error main scan YELLOW R
The pitch data is not in the specified allowable range.
87
MAIN YELLOW REAR
Adjustment value error main scan
YELLOW R
The calculation result value is not in the specified allowable
range.
88
MAIN YELLOW REAR
Result value error main scan
YELLOW R
The variation of the calculation result value is over the
specified allowable range.
Other error
99
OTHER
Other error
Other error
Error
code
Error display
Error content
Detail of content
0
SIMULATION
NO.50-22
TEST
AUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
EXECUTE
MAIN F
MAIN R
SUB
PHASE
C
105.0 (+0.2)
110.0 (-0.1)
103.0 (+0.4)
4 (3)
M
100.0 (+0.0)
99.0 (-0.2)
99.0 (+0.2)
Y
98.0 (+0.3)
98.0 (+0.1)
105.0 (+0.0)
1/1
CLOSE
REGIST
DRUM POS
ALL
0
SIMULATION NO.50-22
TEST
AUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
CLOSE
EXECUTE
NOW EXECUTING…
0
SIMULATION NO.50-22
TEST
AUTO ADJUSTMENT OF REGISTRATION&DLUM POSITION
CLOSE
EXECUTE
PRESS [EXECUTE] TO START
ERROR : TONNER EMPTY 01