MX-2300/2700 N/G PHOTOCONDUCTOR SECTION i – 5
4)
Disengage the lock pawl with a screwdriver, and remove the
MC cleaner shaft.
5)
Release the pawl, and remove the process cover. Remove the
MC charger unit.
c. Side seal F, R
d. Toner reception seal
1)
Remove each drum unit from the machine.
2)
Remove the OPC drum.
3)
Remove the MC charger unit.
4)
Remove the side seal F/R and the toner reception seal.
* When attaching the side seal F/R and the toner reception
seal, arrange so that they are in the ranges specified in the
figure below.
e. Cleaner blade
1)
Remove each drum unit from the machine.
2)
Remove the OPC drum.
3)
Remove the MC charger unit.
4)
Remove the side seal F/R and the toner reception seal.
5)
Remove the screws, and remove the cleaner blade.
6)
Remove the toner mixing sheet from the cleaner blade.
* Tighten the screws according to the marks 1, 2, and 3.
(2) Others
a. Waste toner drive motor
1)
Remove the frame cover. (Refer to Frame Cover in External
Outfit Section.)
2)
Remove the connector and the screws, then remove the waste
toner drive unit.
Remove the screw, and remove the waste toner drive motor
from the waste toner drive unit.
1
2
3
0 - 0.5mm
0 - 0.5mm
0 - 0.5mm
0 - 0.3mm
0 - 0.3mm
0 - 0.3mm
Reference
line
Reference line
Reference line
Reference line
Reference line
2
3