MX-2300/2700 N/G SIMULATION 7 – 118
63-5
Purpose
: Adjustment
Function (Purpose)
: Used to reset the gamma correction and
color correction parameters of the SCAN
ASIC.
Section
: Scanner
Item
: Clear
Operation/Procedure
1)
When a touch panel button to execute the standard reset is
pressed ([SIDE A(OC)] in this example), the selected button is
highlighted and [EXECUTE] button becomes active from the
gray-out display.
* When the selected button is pressed again, selection is can-
celed and the button returns to the normal display.
* If no button is selected for standard reset, [EXECUTE] but-
ton grays out.
* Two or more items can be selected for standard reset.
2)
Press [EXECUTE] button.
[EXECUTE] button is highlighted and [YES] and [NO] buttons
become active.
3)
Press [YES] button.
The scanner color balance standard value reset is executed.
[YES] button is highlighted.
* When [NO] button or [EXECUTE] button is pressed, [EXECUTE]
button returns to the normal display, and [YES] and [NO] buttons
gray out.
* The restored data are saved to EEPROM and RAM.
* During the scanner color balance standard value reset, [EXE-
CUTE] and [YES] buttons are highlighted.
* After completion of the scanner color balance standard value
reset delete, [EXECUTE] button returns to the normal display
and [YES] and [NO] buttons gray out.
<Standard value reset item>
63-6
Purpose
: Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose)
: Used to scan the engine color balance auto
adjustment pattern and to display the sam-
pling result.
Section
: Image process (ICU)
Item
: Image quality (Color balance)
Operation/Procedure
1)
Put the chart self-printed with SIM46-21 on the glass table,
and press [EXECUTE] button. Sampling is started. (When
[EXECUTE] button is pressed during execution, the operation
is interrupted.)
* During sampling, [EXECUTE] button is highlighted.
* The sampling value of each patch from the high density side
is displayed as the result.
When [K][C][M][Y] button is pressed on the sampling result
display screen, the data of each color are displayed.
Only one color button can be selected. (In the initial screen,
[K] is selected.)
* After completion of sampling, [EXECUTE] button returns
to the normal display.
63-7
Purpose
: Setting
Function (Purpose)
: Used to display and register the engine
auto density adjustment scanner target
value.
Section
: Image process (ICU)
Item
: Image quality (Color balance)
Operation/Procedure
1)
When the machine enters Simulation 63-07, the following
screen is displayed.
* Press [K][C][M][Y] button to display the data of each color.
Only one color button can be selected. The selected button
is highlighted. (In the initial screen, [K] is selected.)
2)
When [SETUP] button is pressed, the display is shifted to the
sampling start screen.
Put the chart self-printed with SIM46-21 on the glass table,
and press [EXECUTE] button. [EXECUTE] button is high-
lighted and the sampling screen is displayed.
3)
After completion of sampling, the sampling result is displayed.
When [REPEAT] button is pressed, the display is shifted to the
sampling start screen.
4)
When [OK] button is pressed, the displayed result of sampling
is saved to EEPROM and RAM as the target value.
<Display data content>
* BASE is displayed only on the sampling result display screen.
1
SIDE A
(OC)
Copy gamma correction 1 and color correction
coefficient
2
TWAIN gamma correction 1 and color correction
coefficient
3
Auto adjustment gamma correction 1 and color
correction coefficient
ARE YOU SURE?
YES
NO
EXECUTE
0
SIMULATION
NO.63
̆
05
TEST
STANDARD
SCANNER GAMMA SETUP
1/1
SIDE
A
㧔
OC
㧕
CLOSE
Display data
Display content
B
Point B target value
C
Point C target value
D
Point D target value
E
Point E target value
F
Point F target value
G
Point G target value
H
Point H target value
I
Point I target value
J
Point J target value
K
Point K target value
L
Point L target value
M
Point M target value
N
Point N target value
O
Point O target value
BASE
Base sampling value
0
SIMULATION
NO.63
̆
06
TEST
ENGINE
COLOR BALANCE CHART READING
CLOSE
EXECUTE
SET THE CHART ON PLATEN AND TOUCH [EXECUTE]