MX-2300/2700 N/G SIMULATION 7 – 108
53
53-6
Purpose
: Adjustment
Function (Purpose)
: Used to adjust the RSPF document tray
size of the main unit.
Section
: RSPF
Item
: Operation
Operation/Procedure
1)
Set the tray document guide to the max. width position, and
press [EXECUTE] key. The button is highlighted and the tray
size volume maximum value adjustment is started.
* During the adjustment, "EXECUTING..." is displayed.
* After completion of the tray size volume maximum value
adjustment, the set value is saved to EEPROM and RAM
and the display is shifted to the tray volume A4R size adjust-
ment value start screen. (Each set value is saved to
EEPROM and RAM at each setting.)
2)
Set the tray document guide to A4R (11 x 8.5R) width position
and press [EXECUTE] button. The pressed button is high-
lighted and the tray A4R size adjustment is started.
3)
Adjust the tray volume A5R size and the tray size volume min-
imum value according to the above procedures.
4)
After completion of the adjustment, "COMPLETE"is displayed.
If the adjustment is not completed normally for any rea-
son,"ERROR"is displayed. In that case, the adjustment must
be executed again.
<Adjustment item and content>
When one of 1-4 in the above table is selected, the guide plate is
shifted to each position of the four widths of the guide plate shown
in the table below. The value of the document width sensor
(RSPF_WIDTH) A/D value is saved to EEPROM.
<Guide plate positions and widths on the mechanism and A/D
values to be saved>
53-7
Purpose
: Adjustment
Function (Purpose)
: Used to enter the adjustment value of the
main unit RSPF document tray size adjust-
ment value. SIM53-06 A/D value manual
input (for RSPF).
Section
: RSPF
Item
: Operation
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK], [
↑
], [
↓
] button, [COLOR], or [BLACK] key is
pressed, the currently entered value is set.
<Display item, set range, and default values>
* A/D is 10 bit.
53-8
Purpose
: Adjustment
Function (Purpose)
: Used to adjust the RSPF scan position.
Section
: RSPF
Item
: Adjustment
Operation/Procedure
1)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
2)
When [OK] button is pressed, the currently entered value is
set.
<Display item, set range and default value>
• When the set value is increased by 1, the distance between the
home position and the RSPF scan position is increased by
0.1mm.
No.
Display
Content
1
TRAYVOLMAX
Tray size volume maximum value
2
TRAYVOLA4R
Tray volume A4R size adjustment value
3
TRAYVOLA5R
Tray volume A5R size adjustment
4
TRAYVOLMIN
Tray size volume minimum value
No.
Guide plate
position
Widths on the mechanism
A/D value,
code in
the figure
below
Remark
AB
series
INCHI
series
Code in the
figure below
1
Maximum
position
303.3
303.3
WIDTH_MAX
AD_MAX
2
Middle
position (L)
210
215,9
WITH_P1
AD_P1
A4R OR
LTR
3
Middle
position
(S)
148.5
139.7
WITH_P2
AD_P2
A5R OR
INVR
4
Minimum
position
118
118
WITH_MIN
AD_MIN
0
SIMULATION
NO.53
̆
06
TEST
SPF TRAY ADJUSTMENT
CLOSE
EXECUTE
TRAYVOLMAX TRAY ADJUSTMENT.
PRESS [EXECUTE] TO START
Item
Display
item
Guide plate position
Set range
Default
value
A
AD_MAX
Maximum position
0 to 1023
791
B
AD_P1
Middle position (L)
0 to 1023
713
C
AD_P2
Middle position (S)
0 to 1023
456
D
AD_MIN
Minimum position
0 to 1023
66
Item
Display item
Description
Set
range
Default
value
A
ADJUST VALUE
SPF scan position
adjustment
1 to 99
50
CLOSE
0
A:
A
㧦
791
B
㧦
456
C
㧦
713
D
㧦
791
;
AD_MAX
;
AD_P1
;
AD_P2
;
AD_MIN
SIMULATION NO.53-07
SPF TRAY ADJUSTMENT(MANUAL).
791
[
0~ 1023
]
OK
TEST