MX-2300/2700 N/G SIMULATION 7 – 46
<Fusing temperature setting range and default values>
*1: Japan, China, AB-B
*2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A
43-20
Purpose
: Setting
Function (Purpose)
: Used to correct the environments of low
temperature and low humidity (L/L) for the
fusing temperature setting 1 for each paper
(SIM 43-01).
Section
: Fusing
Item
: Operation
Operation/Procedure
1)
When the machine enters Simulation 43-20, the screen on the
right is displayed. (The current set value is displayed.)
2)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4)
When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [
↑
], [
↓
], [COLOR], or [BLACK] key is pressed, the cur-
rent set value is saved to EEPROM and RAM.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Correction value: (–49 to +49) Input value: Actually entered value
(1 to 99)
<List of setting parameters>
Item
Display
Content
Set
range
Default value
Group
A *1
Group
B *2
A
HL_UM PLAIN
PAPER BW
DUP
BW plain paper
duplex TH_UM
set value
70 to 230
170
175
B
HL_LM PLAIN
PAPER BW
DUP
BW plain paper
duplex TH_LM
set value
30 to 200
100
100
C
HL_US PLAIN
PAPER BW
DUP
BW plain paper
duplex TH_US
set value
70 to 230
175
180
D
PLAIN PAPER
BW DUP APP
CNT
BW plain paper
duplex applicable
number of sheets
0 to 60
1
1
E
HL_UM PLAIN
PAPER CL
DUP
COLOR plain
paper duplex
TH_UM set value
70 to 230
170
175
F
HL_LM PLAIN
PAPER CL
DUP
COLOR plain
paper duplex
TH_LM set value
30 to 200
100
100
G
HL_US PLAIN
PAPER CL
DUP
COLOR plain
paper duplex
TH_US set value
70 to 230
175
180
H
PLAIN PAPER
CL DUP APP
CNT
COLOR plain
paper duplex
applicable
number of sheets
0 to 60
1
1
TH_UM
Fusing upper thermister main
TH_LM
Fusing lower thermister main
TH_US
Fusing upper thermister sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
0
A:
A : 170
B: 100
C: 175
D : 1
㧧
HL_UM
PLAIN PAPER BW DUP
㧧
HL_LM PLAIN PAPER BW DUP
㧧
HL_US PLAIN PAPER BW DUP
㧧
PLAIN PAPER BW DUP APP CNT
SIMULATION
NO.43-04
FUSER TEMP SETUP2 FOR PAPER
170
㨇
70
㨪
230
㨉
OK
TEST
CLOSE
Correction value
–49
–25
–5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display item
Item content
Set
range
Default
value
A
HL_UM READY
LL
Correction value for
TH_UM set value in Ready
standby under LL
environment
1 to 99
55
B
HL_LM READY
LL
Correction value for TH_LM
set value in Ready standby
under LL environment
1 to 99
55
C
HL_US READY
LL
Correction value for TH_US
set value in Ready standby
under LL environment
1 to 99
55
D
HL_UM PLAIN
BW LL
Correction value for BW
plain paper TH_UM set
value under LL
environment
1 to 99
55
E
HL_LM PLAIN
BW LL
Correction value for BW
plain paper TH_LM set
value under LL
environment
1 to 99
55
F
HL_US PLAIN
BW LL
Correction value for BW
plain paper TH_US set
value under LL
environment
1 to 99
55
G
HL_UM PLAIN
CL LL
Correction value for
COLOR plain paper
TH_UM set value under LL
environment
1 to 99
55
H
HL_LM PLAIN
CL LL
Correction value for
COLOR plain paper TH_LM
set value under LL
environment
1 to 99
55
I
HL_US PLAIN
CL LL
Correction value for
COLOR plain paper TH_US
set value under LL
environment
1 to 99
55
J
WARMUP
FUMON
HL_UM T LL
Correction value for fusing
motor front rotation start
TH_UM set value under LL
environment
1 to 99
60
K
WARMUP
FUMOFF
HL_LM T LL
Correction value for fusing
motor front rotation start
TH_LM set value under LL
environment
1 to 99
55
L
WARMUP END
TIME LL
Correction value for
WARMUP complete time
under LL environment
1 to 99
80
M
HL_UM HEAVY
LL
Correction value for heavy
paper TH_UM set value
under LL environment
1 to 99
60
N
HL_LM HEAVY
LL
Correction value for heavy
paper TH_LM set value
under LL environment
1 to 99
60